Configuring Advanced or Mutual CHAP on a Linux Server with NICs

CAUTION

CHAP security must be enabled on the storage systembefore using the Configure iSCSI connections on the Server Utility.

After entering CHAP data on the target, you must enter the same data for the NIC initiators.

STEP 1. Open the /etc/iscsi.conf file on your server with vi or another editor.

STEP 2. For each NIC initiator in the server, enter the initiator CHAP user account data (username and secret) that the initiator sends to the target for authentication.

This data is one of the initiator usernames and secrets that you entered on the target. When the initiator sends this data, the target compares it with an account database and authenticates the initiator.

The following example in the Authentication Settings section of the iscsi.conf file shows advanced CHAP.

Username=john

Password=welcome

#or OutgoingUsername=john OutgoingPassword=welcome

The following example in the Authentication Settings section of the iscsi.conf file shows advanced CHAP, which lets you set different usernames and secrets for each host initiator. The first part shows one storage system; each SP has a different username and password. The second part shows three storage systems; two use one username and password, and the third uses a different username and password.

DiscoveryAddres=127.0.0.1 (Storage System1 SPA) Username=john

Password=welcome

DiscoveryAddres=127.0.0.2 (Storage System1 SPB) Username=betty

Password=bienvenue

#

# or

DiscoveryAddress=127.0.0.1 (Storage System1 SPA) DiscoveryAddress=127.0.0.2 (Storage System1 SPB) DiscoveryAddress=127.0.0.3 (Storage System2 SPA) DiscoveryAddress=127.0.0.4 (Storage System2 SPB)

Username=john

Password=welcome

DiscoveryAddress=127.0.0.5 (Storage System3 SPA) DiscoveryAddress=127.0.0.6 (Storage System3 SPB)

152

Intel Storage System SSR212PP User Guide

 

Revision 1.0

Page 166
Image 166
Intel SSR212PP manual Username=john Password=welcome