STEP 10. Click View mutual CHAP credentials and confirm that the new CHAP entry exists.

STEP 11. Enable advanced CHAP on the storage system:

a.In the Navisphere Express navigation pane, under Manage, click iSCSI to open the

Manage iSCSI screen.

b.Under Security, click Advanced.

c.In the iSCSI Security - Advanced screen, click Enable.

Configuring Basic Chap on a Windows Server with NICs

CAUTION

CHAP security must be enabled on the storage systembefore using the Configure iSCSI connections on the Server Utility.

After entering CHAP data on the target, you must enter the same data on each NIC initiator you log on to. On each initiator, you enter the initiator CHAP user account data (username and secret) that the initiator sends to the target for authentication. For basic initiator CHAP, this data is the initiator username and secret that you entered on the target. When the initiator sends this data, the target compares it with an account database and authenticates the initiator.

STEP 1. Log off and remove iSCSI targets using the instructions in "Removing iSCSI Targets" on page 138.

STEP 2. On the server, open the Navisphere Server Utility. See Procedure 30, "Running the Navisphere Server Utility," on page 165.

STEP 3. Select Configure iSCSI Connections on this server and click Next.

STEP 4. Select Configure iSCSI Connections and click Next.

STEP 5. In the iSCSI Targets and Connections window, select one of the following options to discover the iSCSI target ports on the connected storage systems:

Discover iSCSI targets on this subnet scans the current subnet for all connected SSR212PP2f-Series iSCSI storage system targets. The utility scans the subnet in the range from 1 to 255. For example, if the current subnet is 10.12.77, the utility will scan the IP addresses from 10.12.77.1 to 10.12.77.255.

If CHAP authentication is enabled on all target ports on a storage system, you cannot discover using a subnet scan. You must discover the targets using the target portal.

Discover iSCSI targets for this target portal discovers targets known to the specified iSCSI SP data port.

142