UPS (SP A only)
+ -
Service LAN
COM 1 or COM 2
EMC3345
FIGURE 62. Connecting a Server or Laptop COM Port to an SP Service Port
STEP 3. Start a HyperTerminal session.
A HyperTerminal session lets you communicate with a device in this case an SP connected over a COM port to a Windows server or laptop station.
If you do not have a Windows station available, you can use terminal emulator software for Linux systems. The remainder of this guide describes the steps you would encounter using HyperTerminal on a Windows server or laptop; the procedure for other systems is similar.
a.To start a HyperTerminal session, follow this path:
Start Programs Accessories Communications Hyperterminal
b.When the software asks for a name, create a meaningful name (for example, SSR212PP2f), and then click OK. The software displays a Connect to screen.
c.In the Connect using box, select COM1 or COM2 from the
d.Select the following settings:
Bits per second: 9600
Data bits: 8
Parity: None
Stop bits: 1
Flow Control: None
e.Click OK. The HyperTerminal session is now running, as you can see from the timer displayed at the lower left of the screen. You use this session to communicate with the SP.
STEP 4. Reset the problem SP, and watch for the alphabetic powerup test display in the HyperTerminal window.
Intel Storage System SSR212PP User Guide | 171 |