Configuring HBA initiators on Windows servers for iSNS

Use the use QLogic SANsurfer package to configure the network parameters for each HBA iSCSI initiator

STEP 1. Open QLogic SANsurfer as described in the QLogic documentation.

STEP 2. In the HBA tree, select the HBA and click the HBA Options tab.

The iSCSI name defaults to the iSCSI standard (iqn.xxxx).

STEP 3. Select Enable iSNS.

STEP 4. For each iSNS server, set the iSNS server address automatically or manually:

For an automatic setting: Select Obtain iSNS server address automatically (via

DCHP).

For a manual setting: Select Use the following iSNS server address and enter the IP address of the server.

STEP 5. Click Save to save the new settings.

STEP 6. On the Target Settings tab, verify that the targets were discovered.

If any target was not discovered, verify that the IP address for each iSNS server is correct and that iSNS is set up correctly on the server.