v.Select the IP address of the Inactive target and click Remove. All targets for the storage system are removed.

vi.Click Cancel to close the wizard.

STEP 2. On a Windows server with iSNS, log off and remove targets:

a.On the server that includes your iSCSI initiators, open the Microsoft iSCSI Software Initiator.

b.Log off any connected targets you are setting up for CHAP:

i.On the Targets tab, click Details and log off all targets.

ii.On the Persistent Targets tab, remove any persistent targets.

Setting Up Basic Initiator CHAP on the Storage System

With basic CHAP security, the storage systemuses the same username and secret to authenticate all host initiators. CHAP credentials are configured for the entire storage system, and are required for CHAP security.

STEP 1. On your storage system management station, start Navisphere Express on the storage system that you are configuring. See Procedure 29, "Running Navisphere Express," on page 163.

STEP 2. In the Navisphere Express navigation pane, under Manage, click iSCSI to open the Manage iSCSI screen.

STEP 3. To set basic security, click Basic.

STEP 4. In the iSCSI Security - Basic screen, click Initiator CHAP Configuration.

STEP 5. In the Initiator CHAP Configuration - Basic screen, click Add. The Add Initiator CHAP Credentials - Basic screen opens.

STEP 6. In Step 1 on the screen, enter a CHAP username. This name must match the username for the server s iSCSI initiators.

STEP 7. In Step 2 on the screen, enter and confirm a CHAP secret.

You will enter this secret on the server later.

You can specify the secret in ASCII or hexadecimal characters. ASCII secrets must consist of at least 12 and no more than 16 characters. Hexadecimal secrets must consist of at least 12 and no more than 16 pairs of data (24 to 32 characters). If you specify the CHAP secret using hexadecimal characters, you must select CHAP Secret Specified In Hex.

STEP 8. In Step 3 on the screen, click Apply to add the CHAP credential and return to the Add Initiator CHAP Credentials - Basic screen.

STEP 9. Click View all initiator CHAP credentials and confirm that the new CHAP entry exists.