4: Configuration Using Web Manager

Figure 4-12. Line 1 Command Mode

2. Enter or modify the following fields:

Always

Select Yes to enable the XPort AR’s command mode.

 

 

Use Serial String

Select Yes to start command mode based on a serial string.

 

 

Use CP Group

Select Yes to start command mode based on the value of a

 

CP group.

 

 

Echo Serial String

Select Yes to enable echoing of the serial string at boot-up.

 

 

Wait Time

Enter the wait time for the serial string during boot-up.

 

 

Serial String

In the Char field, enter the serial string characters. Select the

 

string type from the pull down menu as Character, Binary, or

 

Decimal notation.

CP Group

Enter the CP group name and its value.

 

 

Signon Message

In the Char field, enter the boot-up signon message. Select

 

the string type from the pull down menu as Character,

 

Binary, or Decimal notation.

3.In the Current Configuration table, clear currently stored fields as necessary.

4.Click Submit. Changes are applied immediately to the XPort AR.

Tunnel 1 and Tunnel 2 Settings

Select the Tunnel 1 or Tunnel 2 link on the left menu bar to display the Tunnel menu. The sub-menus allow for the configuration of serial settings, connect mode,