SCSI Description
5-64 Maxtor Atlas 10K III
This page defines the methods used by the disk drive to control the reporting and
operations of specific informational exception conditions. This page applies only to
informational exceptions that report an additional sense code of FAILURE
PREDICTION THRESHOLD EXCEEDED to the application client.
Informational exception conditions occur as the result of vendor-specific events
within a disk drive. An informational exceptio n condition may occur asynchronou s to
any comman ds is sued by an app lication client.
The data format and field descriptions are described in Table 5-80 and Table 5-81
respectively. The Codes Used by the MRIE Field are described in Table 5-82.
Inform ati o n Exce p t i o ns C o nt rol Page-(Pa g e 1 Ch )
0 PS Page Code (1Ch)
1 Page Length (0Ah)
2 Perf Reserved EWASC DExcpt Test Rsvd LogErr
3 Reserved MRIE
4 - 7 (MSB) Inter val Ti me r (LSB)
8 11 (MSB) Report Count (LSB)