￿￿￿￿94+6'￿￿￿￿￿￿%QOOCPF￿￿￿#J￿The WRITE (10) command requests that the drive write initiator-supplied data to the medium. The data format and field descriptions are shown in Table 5-214and Table 5-215respectively.

WRITE (10) Command Descriptor Block-Data Format

 

 

 

 

 

 

 

 

 

 

0

 

 

Operation Code (2Ah)

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

Reserved

 

DPO

FUA

 

Reserved

RelAdr

 

 

 

 

 

 

 

 

 

 

2 - 5

 

 

Logical Block Address

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Reserved

 

 

 

 

 

 

 

 

 

 

 

7 - 8

 

 

 

Transfer Length

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Control

 

 

 

 

 

 

 

 

 

 

 

 

 

$[VG$KV

￿

￿WRITE￿(10) Command￿

-Field￿Descriptions￿

￿

￿

 

 

 

 

 

 

 

 

 

 

 

Disable Page Out. When the value of the field is 1, the drive tells the control-

 

 

 

ler to bypass cache as much as possible. The buffers used for the WRITE

 

 

 

data are given a low priority. This bit may be useful if the host CPU is per-

 

 

 

forming a background copy operation and does not want to wipe out the

(KGNFDPO

 

 

drive's cache.

 

 

 

 

 

&GUETKRVKQP

 

 

Table5

-214When DPO is 0, the drive tells the controller to cache this WRITE data in a

 

 

 

normal manner.

 

 

 

 

 

 

NOTE: The drive normally assigns a low priority to write caching. Therefore,

 

 

 

the DPO bit in a WRITE command is ignored.

 

 

 

 

 

 

 

 

 

Force Unit Access. When 1, the data must be written on the medium before

 

 

 

GOOD status is returned. When 0, GOOD status may be returned after the

FUA

 

 

data is fetched from the initiator and before it is written to the medium. If

 

 

the WCE (Write Cache Enable) bit on the MODE SELECT command Caching

 

 

 

 

 

 

Page is clear, the FUA bit is ignored and behaves as if it were always set (that

 

 

 

is, if WCE = 0, the controller forces FUA = 1).

 

 

 

 

 

 

 

 

Logical Block

 

The address of the first logical block where the Write operation will occur.

Address

 

 

 

 

 

 

 

 

 

 

 

 

RelAdr

 

 

Relative Address. This drive does not support this feature; the field must be

 

 

0.

 

 

 

 

 

 

 

 

 

 

Table5-215

 

The number of contiguous logical blocks of data to write. The drive returns

Transfer

 

 

CHECK CONDITION status with the correct sense data if the specified trans-

Length

 

 

fer would cause the write operation to extend beyond the Logical Block Ad-

 

 

 

dress space.

 

 

 

 

 

 

 

 

 

 