Specifications
Maxtor Atlas 10K III 4-9
5 Volts / m eter @ 100 MHz.
The drive functions normally when any exposed metal is subjected to
electrostatic discharge excluding the PCB. This electrostati c dis charge must be at
a minimum interval of 30 seconds, either from a 150pF capacitor discharged
through a 150K resistor or from a 1 00pF capacitor through a 500k resistor.
The Maxtor Atlas 10K III family of drives meets all specification s with a 6 gauss
field applied in any environment at 100 kHz.
0 5kV Average of <0.3 soft errors p er di scharge
5 10 kV Average of <1.0 soft error s per disch arge
10 20 kV No perman en t degrad ation