SCSI Description

￿￿￿￿￿￿4KIKFThe￿&KUMRigid)GQOGVT[Disk Geometry￿2CIGPage￿￿￿describesJ￿the drive geometry. The data format and field descriptions are described in Table 5-96and Table 5-97respectively.

 

 

 

 

 

Rigid Disk Geometry Page-(Page 4)

 

 

 

 

 

 

 

 

 

 

 

 

 

0

PS

Table5-96

 

 

 

 

Page Code (04h)

 

Rsvd

 

 

 

 

 

1

 

 

 

 

Page Length (16h)

2

-

 

 

 

Number of Cylinders

 

5

 

 

 

 

Number of Heads

6

- 8

 

 

Starting Cylinder - Write Precompensation

9 - 11

 

 

Starting Cylinder - Reduced Write Current

12

- 13

 

 

 

 

Drive Step Rate (0)

14

- 16

 

 

 

Landing Zone Cylinder

17

 

 

 

Reserved

 

 

 

RPL

 

 

 

 

 

 

 

 

18

 

 

 

 

Rotational Offset

 

 

 

 

 

 

 

19

 

 

 

 

 

Reserved

 

 

 

 

 

 

20

- 21

 

 

 

Medium Rotation Rate

 

 

 

 

 

 

 

 

22

- 23

 

 

 

 

 

Reserved

 

 

 

 

 

 

 

 

 

 

 

 

$[VG

$KV

￿

Rigid Disk Geometry￿

Page￿-Field Descriptions￿

(Page￿4) ￿

￿

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameters Savable. This bit is only used with the MODE SENSE

(KGNFPS

 

 

8CNWG1

 

command. A returned value&GUETKRVKQPof 1 indicates that the target is ca-

 

 

 

 

 

pable of saving the page in a non-volatile, vendor-specific loca-

 

 

 

 

 

tion. The bit is reserved with the MODE SELECT command.

 

 

 

 

 

 

 

Number of Cylin-

17338

 

The number of physical cylinders that hold host data.

 

ders

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Number of Heads

3/5/10/20

The number of heads that can access host data.

 

 

 

 

 

 

Starting Cylinder

17338

 

The value in this field is the physical cylinder at

 

 

 

 

 

 

 

Write

 

 

 

 

which write precompensation is to begin. The first cylinder num-

 

 

 

 

ber is 0. If the starting cylinder is equal to the value in the Number

Precompensation

 

 

 

 

of Cylinders field, write precompensation is disabled.

 

 

 

 

 

 

 

 

 

 

 

Starting Cylinder -

 

 

The value in this field is the physical cylinder at which write cur-

Reduced Write

 

0

 

rent is reduced. The first cylinder number is 0. If the starting cyl-

Current

 

 

 

inder for reduced write current is equal to the value in the Number

 

 

 

 

 

 

 

 

 

of Cylinders field, reduced write current is disabled.

 

 

 

 

 

 

 

Drive Step Rate

 

0

 

Applies to stepper-motor actuators. Not applicable.

 

 

 

 

 

 

 

 

 

 

 

 

This field indicates a two’s complement location where the drive

 

 

 

 

 

positions the disk heads. A negative value indicates that the

Landing Zone

 

17338

 

heads are positioned below cylinder 0 by that number of cylin-

Cylinder

 

 

 

ders. A positive value greater than the number of cylinders indi-

 

Table5-97

 

 

 

 

cates that the heads are positioned beyond the cylinders used for

 

 

 

 

 

data storage at the location specified.

 

 

 

 

 

 

 

 

 

 

 

5-80 Maxtor Atlas 10K III