SCSI Description

 

 

 

 

 

(KGNF

 

&GHCWNV

 

&GUETKRVKQP

 

 

 

Disable Reassign Copy. When this field = 0, the disk drive copies best-

 

 

 

guess data to the new physical block during REASSIGN BLOCKS command

 

 

 

processing. If the disk drive cannot successfully read the original block’s da-

DRC

 

0

ta, the disk drive sets a Forced Error flag in the replacement block’s flags.

 

 

 

When this field = 1, the disk drive does not copy a block’s data and obtain

 

 

 

best-guess data; it first reassigns the block and then writes data to the

 

 

 

block. Until it is overwritten by a subsequent WRITE command, a reassigned

 

 

 

block’s data is undefined and its Forced Error flag is set.

NMAIOP

 

0

No MAIOP. When this field = 1, MAIOP is disabled.

DNTRA

 

0

Disable Next Track Read Ahead. Do not prefetch next track.

Soft Fault

 

0

When this field is set = 1, the disk drive’s FAULT led illuminates.

 

 

 

Manual Calibration. When set = 0, the disk drive runs calibration and diag-

 

 

 

nostic procedures periodically.

 

 

 

When set = 1, calibrations occur only as a result of a REZERO UNIT com-

ManCal

 

0

mand.

 

 

 

 

Note that this bit is not saved by MODE SELECT when the value of the SP

 

 

 

field is 1.

 

 

 

 

 

DPER

 

1

Disable Post Error Recovery. When set = 1, disables Post Error Recovery

 

(refer to Read-Write Error Recovery Page, Section 5.17.3.3).

 

 

 

 

 

 

 

 

 

 

Force AxRE where x = W (WRITE) or (READ)

 

 

 

When set = 0, the settings of AWRE/ARRE are as set in Mode Page 01h

FAxRE

 

1

(Read-Write Error Recovery Page).

 

 

 

When set = 1, Automatic WRITEs or READs are forced, even if the related

 

 

 

fields of Mode Page 01h are = 0.

 

 

 

 

 

 

 

Quick Disk Error Recovery. When set = 0, disk error recovery has no

QDER

 

0

20msec limit.

 

 

 

 

When set = 1, disk error recovery time allotted is less than 20msec.

 

 

 

 

 

 

 

Disable Format Certification. If set = 1, format certification is disabled re-

DFC

 

0

gardless of the value of the DCRT bit in the FORMAT Command’s parameter

 

 

 

header.

 

 

 

 

 

 

Read Ahead

 

0

If set = 1, disables READ ahead.

Disable

 

 

 

 

 

 

 

 

 

 

Enable

 

 

 

 

Double Ack

 

0

If set = 1, enables the double acknowledge filter.

Filter

 

 

 

 

 

 

 

 

ESPDis

 

0

ESP Disabled. If this field = 1, ESP (anticipatory READ) is disabled.

 

 

 

 

DFRCSU

 

0

Disable Filling of Revector Cache on Spin-Up. When this field = 1, revec-

 

toring cache is not refilled on spin-up.

 

 

 

 

 

 

 

 

 

 

Asynchronous Information Protection (AIP) Generation Disabled. When =

AIP Gen

 

0

0, drive places AIP information on the upper byte of data during asynchro-

Disable

 

nous information phases, regardless of the setting of “AIP Check Enabled.”

 

 

 

 

 

When set = 1, AIP generation is disabled.

 

 

 

 

 

 

 

AIP Checking Enabled. When = 0, the drive will ignore AIP information for

 

 

 

this initiator. When = 1, the drive is able to validate incoming AIP informa-

 

 

 

tion on upper byte of data during asynchronous information phases and can

AIP Check

 

0

generate errors on bad information.

 

 

 

Enabled

 

NOTE

 

 

 

 

 

 

 

 

 

 

 

This bit is maintained uniquely for each unique initiator ID that senses or se-

 

 

 

lects it. All initiators that want to participate in AIP must set this bit for

 

 

 

themselves.

 

 

 

 

 

AIP Capable

 

1

When = 0, indicates that drive does not support AIP. If = 1, indicates drive

 

is capable of AIP.

 

 

 

 

 

 

 

 

 

 

 

 

When this field = 0, “total bytes read/written” field on Log Page 02h and

LogPgB

 

0

03h reported as number of

. When = 1, field is reported as number of

 

 

 

.

 

 

 

 

 

 

5-70

Maxtor Atlas 10KDNQEMUIII

D[VGU

Page 134
Image 134