Information Exceptions Control Page-Field Descriptions (Page 1Ch)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameters Savable. This bit is only used with the MODE SENSE command.

 

(KGNFPS

 

&GHCWNV8CNWG1 ￿

A returned value of 1 indicates that&GUETKRVKQPthe target is capable of saving the page

 

 

 

 

in a non-volatile, vendor-specific location. This bit is reserved with the

 

 

 

 

MODE SELECT command.

 

 

 

 

 

 

 

 

 

Performance.Thisbitenables/disablesperformance-sensitivefunctions.For

 

 

 

 

Atlas 10K III, this means enabling or disabling flushing of SMART data to

 

 

 

 

the media (done hourly). The prediction algorithm is designed to reset the

 

 

 

 

current accumulated data approximately every 100,000 blocks read or writ-

 

PERF

 

1

ten per head.

 

 

When this bit = 0, current accumulated SMART data is preserved across

 

 

 

 

 

 

 

 

power cycles.

 

 

 

 

When this bit = 1, current accumulated SMART data is lost across power

 

 

 

 

cycles.

 

 

 

 

 

 

 

 

 

Enable Warning ASC. When this bit = 0, reporting of thermal warming is

 

EWASC

 

1

disabled.

 

 

 

 

 

 

 

When this bit = 1, thermal warning reports are enabled.

 

 

 

 

 

 

 

Table5-81

Disable Exceptions. This bit is used to enable or disable SMART exception

 

 

reporting. When this bit = 0, SMART exception reporting is enabled.

 

DExcpt

0

When this bit = 1, all SMART functions are disabled, including reporting

 

 

 

 

 

 

 

 

SMART exceptions, running the prediction algorithm, and accumulating

 

 

 

 

SMART data.

 

 

 

 

 

 

 

 

 

When this bit = 0, the test function is disabled.

 

Test

0

When this bit = 1, the disk drive reports false SMART trip reports as pre-

 

scribed in the MRIE field (see below). Interval timer field and report count

 

 

 

 

 

 

 

 

and method fields apply. When the test bit forces a SMART failure, the fail-

 

 

 

 

ure is reported with a sense code/qualifier of 5D/FF.

 

 

 

 

 

 

LogErr

0

When this bit = 0, it indicates that log sense information is vendor-unique.

 

NOTE: LogErr = 0 is the only value supported.

 

 

 

 

 

 

 

 

 

 

 

 

 

Method of Reporting Informational Exceptions. The value within this field in-

 

MRIE

4

dicates the method that will be used by the disk drive to report informational

 

exception conditions, as shown in Table 5-82.The relative priority of report-

 

 

 

 

 

 

 

 

ing of multiple informational exceptions is vendor-specific.

 

 

 

 

 

 

 

 

 

This field indicates the period, in 100 millisecond increments, for reporting

 

 

 

 

that an informational exception condition has occurred. The disk drive will

 

 

 

 

not report such conditions more frequently than the time specified by the

 

 

 

 

Interval Timer field and as soon as possible after the timer interval has

 

 

 

 

elapsed. After the condition has been reported, the interval timer restarts.

 

Interval

 

 

A value of 0 in the Interval Timer field indicates that the disk drive will only

 

0

report the informational exception condition once. A value of FFFFFFFFh in

 

Timer

 

 

 

the Interval Timer field indicates that the timer interval is vendor-specific.

 

 

 

 

 

 

 

 

If the disk drive’s predictor detects a SMART threshold trip, it reports the

 

 

 

 

failure only if it has not reported a failure within the last interval timer peri-

 

 

 

 

od. A value of 0 means that there is no required waiting between SMART

 

 

 

 

reports.

 

 

 

 

NOTE: The Interval Timer field does not apply to MRIE mode 6.

 

 

 

 

 