178 Chapter 4 Troubleshooting
In both situations, the BayStack 420 Switch “autosenses” the speed of the connected station and, by default, reverts to
To correct this mode mismatch problem:
1Use the Port Configuration screen to disable autonegotiation for the suspect port (see “Port Configuration screen” on page 129).
2Manually set the Speed/Duplex field to match the speed/duplex mode of the connected station (see Table 24 on page 130).
You may have to try several settings before you find the correct speed/duplex mode of the connected station.
If the problem persists:
1Disable the autonegotiation feature at the connected station.
2Manually set the speed/duplex mode of the connected station to the same speed/duplex mode you have manually set for the BayStack 420 Switch port.
Port interface
Ensure that the devices are connected using the appropriate crossover or