Planet Technology SGSW-24040R, WGSW-24040R Storm Control Configuration, Frame Type, Status, Rate

Models: SGSW-24040R WGSW-24040R

1 308
Download 308 pages 62.4 Kb
Page 131
Image 131

User’s Manual of WGSW-24040 / WGSW-24040R

SGSW-24040 / SGSW-24040R

4.8.7 Storm Control Configuration

Storm control for the switch is configured on this page. There three types of storm rate control:

„Unicast storm rate control

„Multicast storm rate control

„Broadcast storm rate control.

The rate is 2^n, where n is equal to or less than 15, or "No Limit". The unit of the rate can be either pps (packets per second) or kpps (kilopackets per second). The configuration indicates the permitted packet rate for unicast, multicast, or broadcast traffic across the switch.

The Storm Control Configuration screen in Figure 4-8-14appears.

Figure 4-8-14Storm Control Configuration page screenshot

The page includes the following fields:

 

 

 

 

Object

Description

Frame Type

The settings in a particular row apply to the frame type listed here:

 

 

unicast

 

 

multicast

 

 

broadcast.

 

 

 

Status

Enable or disable the storm control status for the given frame type.

 

 

 

Rate

The rate unit is packet per second (pps), configure the rate as 1, 2, 4, 8, 16, 32,

 

 

64, 128, 256, 512, 1K, 2K, 4K, 8K, 16K, 32K, 64K, 128K, 256K, 512K, or 1024K.

 

 

The 1 kpps is actually 1002.1 pps.

 

 

 

 

 

 

 

 

131

Page 131
Image 131
Planet Technology SGSW-24040R, WGSW-24040R user manual Storm Control Configuration, Frame Type, Status, Rate