Planet Technology WGSW-24040R, SGSW-24040R user manual Stacking not functioning Solution

Models: SGSW-24040R WGSW-24040R

1 308
Download 308 pages 62.4 Kb
Page 294
Image 294

User’s Manual of WGSW-24040 / WGSW-24040R

SGSW-24040 / SGSW-24040R

Stacking not functioning Solution:

1.Check that modules are installed correctly

2.PLANET CB-STX50 or CB-STX200 cables not installed correctly (LEDs on front panel STX1 or STX2 do not light)

3.Check that the cables are inserted correctly

4.The stack cable is PLANET proprietary stack cable, the stack cable is cross-overed HDMI-like cable, the normal HDMI cable can’t be used for the SGSW series.

„While IP Address be changed or forgotten admin password

To reset the IP address to the default IP Address “192.168.0.100” or reset the password to default value. Press the hardware reset button at the front panel about 10 seconds. After the device is rebooted, you can login the management WEB interface within the same subnet of 192.168.0.xx.

Reset

294

Page 294
Image 294
Planet Technology WGSW-24040R Stacking not functioning Solution, „ While IP Address be changed or forgotten admin password