Planet Technology WGSW-24040R, SGSW-24040R „ Example 2 Downloading System Software from a Server

Models: SGSW-24040R WGSW-24040R

1 308
Download 308 pages 62.4 Kb
Page 62
Image 62

User’s Manual of WGSW-24040 / WGSW-24040R

SGSW-24040 / SGSW-24040R

„Example 2: Downloading System Software from a Server

When downloading runtime code, you can specify the destination file name to replace the current image, or first download the file using a different name from the current runtime code file, and then set the new file as the startup file.

1.Click System, File Management, Copy Operation.

2.Select “tftp to file” as the file transfer method, enter the IP address of the TFTP server.

3.Set the file type to “opcode,” enter the file name of the software to download, select a file on the Managed Switch to overwrite or specify a new file name and click Apply.

4.If you replaced the current firmware used for startup and want to start using the new operation code, reboot the system via the System/Reset menu.

Figure 4-2-19Download system software screenshot

Figure 4-2-20TFTP Server system software transmit screenshot

62