Planet Technology WGSW-24040R, SGSW-24040R Network Diagnastics, Cable Diagnostics, Cable Status

Models: SGSW-24040R WGSW-24040R

1 308
Download 308 pages 62.4 Kb
Page 194
Image 194

User’s Manual of WGSW-24040 / WGSW-24040R

SGSW-24040 / SGSW-24040R

4.15 Network Diagnastics

4.15.1 Cable Diagnostics

This page is used for running the Cable Diagnostics.

Press to run the diagnostics. This will take approximately 5 seconds. If all ports are selected, this can take approximately 15 seconds. When completed, the page refreshes automatically, and you can view the cable diagnostics results in the cable status table. Note that Cable Diagnostics is only accurate for cables of length 7 - 140 meters.

10 and 100 Mbps ports will be linked down while running cable diagnostic. Therefore, running cable diagnastic on a 10 or 100 Mbps management port will cause the switch to stop responding until VeriPHY is complete. The ports belong to the currently selected stack unit, as reflected by the page header.

 

 

Figure 4-15-1Cable Diagnostics page screenshot

 

 

 

 

 

 

 

 

 

 

 

 

 

Object

 

Description

Port

 

The port where you are requesting Cable Diagnostics.

 

 

 

 

 

 

Cable Status

 

 

 

: Port number.

 

Port

 

 

 

 

: The status of the cable pair.

 

 

 

Pair

 

 

 

 

: The length (in meters) of the cable pair.

 

 

 

Length

 

 

 

 

 

 

 

 

 

 

 

 

 

 

194