User’s Manual of
The page includes the following fields:
|
|
|
Object | Description | |
• | Port | This is the logical port number for this row. |
|
|
|
• | Link | The current link state is displayed graphically. Green indicates the link is up and |
|
| red that it is down. |
•Current Link Speed Provides the current link speed of the port.
•Configured Link Speed Select any available link speed for the given switch port. Draw the menu bar to select the mode.
•Auto Speed - Setup Auto negotiation.
• | 10 half | - Force sets |
• | 10 Full | - Force sets |
•100 half - Force sets
•100 full - Force sets
•1000 full - Force sets
•Disable - Shutdown the port manually.
• | Flow Control | When Auto Speed is selected for a port, this section indicates the flow control |
|
| capability that is advertised to the link partner. |
|
| When a |
|
| • Current Rx column indicates whether pause frames on the port are |
|
| obeyed. |
|
| • Current Tx column indicates whether pause frames on the port are |
|
| transmitted. |
|
| The Rx and Tx settings are determined by the result of the last |
|
| Check the configured column to use flow control. |
|
| This setting is related to the setting for Configured Link Speed. |
|
|
|
• | Maximum Frame | Enter the maximum frame size allowed for the switch port, including FCS. The |
|
| allowed range is 1518 bytes to 9600 bytes. |
•Excessive Collision Configure port transmit collision behavior.
Mode | • Discard: Discard frame after 16 collisions (default). |
| • estart: Restart backoff algorithm after 16 collisions. |
|
|
• Power Control | The Usage column shows the current percentage of the power consumption per |
| port. The Configured column allows for changing the power savings mode |
| parameters per port. |
| • Disabled: All power savings mechanisms disabled. |
| • ActiPHY: Link down power savings enabled. |
| • Dynamic: Link up power savings enabled. |
|
|
78