Q-Logic 8200 SERIES manual To install a new Maintenance Mode image on SANbox SSP

Models: 8200 SERIES

1 118
Download 118 pages 52.72 Kb
Page 69
Image 69

Q

5 – Maintaining the SANbox SSP Interpreting the LED Patterns

5. Choose option i to install the following (or the desired boot set):

t3-patch_1.1.0-15c on bootset 1

6. Choose option r to reboot.

To install a new Maintenance Mode image on SANbox SSP:

The release notes for a given SANbox SSP software release indicate whether an update to Maintenance Mode is necessary. See the release notes for instructions on installing the Maintenance Mode image.

5.5

Interpreting the LED Patterns

Figure 5-1shows the six LED indicator lights on SANbox SSP and the function to which each light corresponds. A green light indicates normal operation.

An amber LED indicates that the corresponding component is missing, has failed, or will likely fail soon. Even if your SANbox SSPs appear to be performing normally, you should replace parts if their corresponding LED has turned amber. See "Replacing Hardware Components" on page 6-6for information about ordering and installing replacement parts.

1 2 3

1

1

! 2

2 3

4 5 6

1Power Supply 1 LED indicator light.

2Alert LED indicator light: amber indicates a temperature alert or an internal voltage fault.

3Power Supply 2 LED indicator light.

4Fan 1 LED indicator light.

5Fan 2 LED indicator light.

6Fan 3 LED indicator light.

Figure 5-1. SANbox SSP LED Panel Indicator Lights (Port Side)

SN0054628-00 A

5-5

Page 69
Image 69
Q-Logic 8200 SERIES manual To install a new Maintenance Mode image on SANbox SSP