SAGEM 3P@C

Table 1-3Parameter table on the modules of SFP optical interface

Type

Rate

Optical

Maximum

Optical

Transmitt

Transmit

Receivi

Receivi

 

(bps)

fiber

transmissio connect

ing

ting

ng

ng

 

 

mode

n distance

or type

center

optical

overlo

sensitivi

 

 

 

 

 

 

waveleng

power

ad

ty

 

 

 

 

 

 

th (nm)

(dBm)

point

((dBm)

 

 

 

 

 

 

 

 

(dBm)

 

SFP-SM-155M-15K

155 M

Single

15

LC

 

1,310

-15 ~ 0

-8

-28

 

 

mode

 

 

 

 

 

 

 

SFP-SM-155M-40K

155 M

Single

40

LC

 

1,310

-5 ~ 0

-10

-34

 

 

mode

 

 

 

 

 

 

 

SFP-SM-155M-80K

155 M

Single

80

LC

 

1,550

-5~0

-10

-34

 

 

mode

 

 

 

 

 

 

 

SFP-SM-622M-15K

622 M

Single

15

LC

 

1,310

-15 ~ 0

-8

-28

 

 

mode

 

 

 

 

 

 

 

SFP-SM-622M-40K

622 M

Single

40

LC

 

1310

-5~ 2

-8

-28

 

 

mode

 

 

 

 

 

 

 

SFP-SM-622M-80K

622 M

Single

80

LC

 

1,550

-5 ~ 2

-8

-28

 

 

mode

 

 

 

 

 

 

 

SFP-SM-1.25G-10K

1.25

Single

10

LC

 

1,310

-5~0

-3

-23

 

G

mode

 

 

 

 

 

 

 

SFP-SM-1.25G-30K

1.25

Single

30

LC

 

1,310

-4 ~ 2

-3

-20

 

G

mode

 

 

 

 

 

 

 

SFP-SM-1.25G-40K

1.25

Single

40

LC

 

1,310

-5 ~ 2

-3

-21

 

G

mode

 

 

 

 

 

 

 

SFP-SM-1.25G-70K

1.25

Single

70

LC

 

1,550

-2~5

-3

-22

 

G

mode

 

 

 

 

 

 

 

SFP-SM-1.25G-110K

1.25

Single

110

LC

 

1,550

0 ~ 5

-9

-30

 

G

mode

 

 

 

 

 

 

 

SFP-SM-2.5G-15K

2.5 G

Single

15

LC

 

1,310

-10 ~ 2

-9

-18

 

 

mode

 

 

 

 

 

 

 

SFP-SM-2.5G-40K

2.5 G

Single

40

LC

 

1,310

-10 ~ 3

-9

-19

 

 

mode

 

 

 

 

 

 

 

SFP-SM-2.5G-70K

2.5 G

Single

70

LC

 

1,550

-10 ~ 3

-9

-19

 

 

mode

 

 

 

 

 

 

 

Table 1-4Parameter table on the modules of XENPAK optical interface

 

 

Type

Rate

Optical

Maximum

Conne

Transmittin

Transmitti

Receivi

Receivi

 

(bps)

fiber

transmis

ctor

g center

ng optical

ng

ng

 

 

mode

sion

Type

wavelength

power

overloa

sensitivi

 

 

 

distance

 

(nm)

 

d point

ty

 

 

 

 

 

 

 

 

(dBm)

(dBm)

Xenpak-SM-10G-10K

10 G

Single

10

SC

1310

-8.2~0.5

0.5

-10.3

 

 

mode

 

 

 

 

 

 

 

8.2.Checking the Status of the User Port

8.2.1.Querying the ADSL Port Status

You can query the ADSL port information by executing the commands below:

„show port [portlistallactive]: Show the current information of the port

„show port [portlistallactive] adsl line-config: Show the configuration information of the

ADSL port

The first command is used to show the current information that is subject to update in real time. The second command is used to show configuration information that does not vary with the port link status.

3P@C Installation Manual

Page 8-2 Reproduction and communication in any form prohibited without the written permission of SAGEM SA