To install the uplink interface module, take the following steps:
Step 1 Place the SMUB on a flat and stable insulating desktop, and remove the baffle plate in the position of the uplink interface.
Step 2 Take out the purchased uplink interface module from the packing box, fix two fixation copper bars and an interface board panel to the interface module with screws, insert the uplink interface of the uplink interface module into the uplink interface of the SMUB, align the pins of the interface module with the SMUB socket, and then push the pins into the socket with even force, as shown in Figure
Figure
Rear side of the uplink
interface module
Connection socket
Connect the uplink interface of the uplink interface module first
SMUB
Then align the pins of the uplink
interface module with the SMUB socket and parallelly press them into the socket
You should hold the edges of the module instead of touching the component or the printed circuits to avoid damage to the component caused by human static
Note electricity.
Step 3 | Fix the module with the |
| the uplink interface module, as shown in Figure |
3P@C Installation Manual