To install the uplink interface module, take the following steps:

Step 1 Place the SMUB on a flat and stable insulating desktop, and remove the baffle plate in the position of the uplink interface.

Step 2 Take out the purchased uplink interface module from the packing box, fix two fixation copper bars and an interface board panel to the interface module with screws, insert the uplink interface of the uplink interface module into the uplink interface of the SMUB, align the pins of the interface module with the SMUB socket, and then push the pins into the socket with even force, as shown in Figure 4-31. Now the screw holes on the four corners of the interface board are aligned with the four screw holes on the SMUB. Get ready to install the screws.

Figure 4-31 Insert the pins of the uplink interface module into the socket of the SMUB

Rear side of the uplink

interface module

Connection socket

Connect the uplink interface of the uplink interface module first

SMUB

Then align the pins of the uplink

interface module with the SMUB socket and parallelly press them into the socket

You should hold the edges of the module instead of touching the component or the printed circuits to avoid damage to the component caused by human static

Note electricity.

Step 3

Fix the module with the special-purpose screws used to install

 

the uplink interface module, as shown in Figure 4-32.

3P@C Installation Manual

Page 4-24