CHAPTER 6

6.System Configuration and Management

6.1.Equipment Power-on

When the 3P@C 4450E is installed, you may power it on. The following phenomena will occur when the equipment is powered on:

„First the RUN indicator of the SMUB will be on, and the RUN indicator of the ADUB/ADUC or the VDUB will start to flash.

„After that, the 3P@C 4450E switch will conduct self-check and begin to load system software. At this time, the “LINK” indicator of a port that has been connected reliably will be solid on while the ACTIVE indicator will be off. About 90 seconds later, the switch enters the normal working state. For the connected port, if the ACTIVE indicator starts flashing, it indicates that this port is transmitting or receiving data.

„If the Console interface is now connected to a PC with a HyperTerminal, then such product information as company name, product serial number and hardware and software versions will be displayed on the PC screen, and operation prompt will be given when the self-check is completed. After you correctly log in the system, you may enter the command line management system to perform 3P@C 4450E configuration and management. For the specific configuration method, please refer to the 3P@C 4450E IP-DSLAM Software Configuration Manual. If the Console interface is not connected to the PC, please refer to the Console interface connection described in Chapter 4.

6.2.Setting Up the Configuration Environment

6.2.1.Local Configuration via the Console Interface

When the 3P@C 4450E is powered on, the system will first complete the self test. If everything is normal, the 3P@COS login interface will appear. The specific procedure is shown as follows:

Step 1 Connect the Console interface on the SMUB to a certain terminal according to the method described in Chapter 4, and conduct the corresponding setting.

Step 2 When the 3P@C 4450E is powered on, such information as company name, production date and product version and some self test information of the system are displayed on the terminal screen first, as shown in the following:

3P@C 4450EV2 Boot Loader Version 2.03 Compiled: May 23 2003 14:46:07 SDRAM test....passed.

Base ethernet MAC address: 00:05:3b:00:04:99

Uncompress start...

3P@C Installation Manual

Page 6-1Reproduction and communication in any form prohibited without the written permission of SAGEM SA