SAGEM 3P@C

 

 

 

 

 

 

 

 

Module type

Name

 

Description

Interface

 

 

 

 

 

 

type

 

 

DS-2FSM

2-port 100M single-

Providing 2 100Base-FX

SC

 

 

 

mode

optical

uplink single-mode optical

 

 

 

 

interface module

interfaces

 

 

 

DS-2FMM

2-port 100M multi-

Providing 2 100Base-FX

SC

 

 

 

mode

optical

uplink multi-mode optical

 

 

 

 

interface module

interfaces

 

 

 

DS-A155SM

1-port long-wave

Providing 1 155M long-wave

SC

 

 

 

single-mode ATM

single-mode uplink ATM

 

 

 

 

optical

interface

optical interface

 

 

 

 

module

 

 

 

 

 

DS-A155MM

1-port short-wave

Providing 1 155M short-wave

SC

 

 

 

multi-mode

ATM

multi-mode uplink ATM optical

 

 

 

 

optical

interface

interface

 

 

 

 

module

 

 

 

 

 

DS-4TXB

4-port

100M

Providing 4 10/100Base-TX

RJ-45

 

 

 

electrical

interface

uplink electrical interfaces

 

 

 

 

module

 

 

 

 

 

DS-4ITX

Value-added

Providing 4 10/100Base-TX

RJ-45

 

 

 

service card

uplink electrical interfaces

 

 

For the detailed description of uplink interface modules, please refer to Section 2.5.

prompt

1.1.1.4Indicators of the SMUB

The front panel of SMUB provides LEDs for indicating the system operating status and the Ethernet interface working status. The administrator can judge the system operation status according to the display of these LEDs so as to diagnose the network fault in time, reduce the operation loss and improve work efficiency. Descriptions of the LED indicators are given in Table 2-4:

Table 2-4 Status definitions of the LED indicators on the SMUB

LED

Identific

Color

Status

Description

 

 

 

ation

 

 

 

 

 

 

System

RUN

Green

Off

The system does not operate

 

running

 

 

Flashin

The system operates normally.

status

 

 

g

 

 

 

 

indicator

ALM

Red

Off

The system operates normally

 

 

 

 

ON

System alarm. This LED flashes

 

 

 

 

once when the equipment is started

 

 

 

 

and conducts self-check. It does

 

 

 

 

not indicate any alarm at this time

Ethernet

LINK

Green

Solid

The corresponding LED is solid on

interface

 

 

on

after a stable connection is set up

working

 

 

 

at the port

 

 

status

 

 

Off

The port is not connected

 

indicators

ACT

Green

Flashin

Data are being received/transmitted

 

 

 

g

on the port

 

 

 

 

 

Off

No

data

are

being

 

 

 

 

received/transmitted on the port

3P@C Installation Manual

Page 2-9Reproduction and communication in any form prohibited without the written permission of SAGEM SA