SAGEM 3P@C

For operation details, see section 7.1.3.

prompt

Step 6: Return to the main menu

After the file is transferred successfully, the above interface disappears. The system returns to the serial port menu. Execute the command x to return to the Bootrom main menu.

Step 6: Reboot the system

Execute the command r in the main menu to reboot the system.

1.1.1.54Upgrade through FTP/Xmodem

After starting the equipment, you can upgrade the system control board through FTP or Xmodem. If the user has separate system control board software, you can upgrade the master system control board separately. The operation is similar to that of upgrading the system file as described in section 7.1.3, except that their file names are different from each other. If the user upgrades the software of the master system control board through the system file, follow the procedures below:

Step 1 Download the system software

For the downloading method, see section 7.1.3 “Upgrading the System

File”.

Step 2 When you upgrade the version of the system control board, the system file is hos_smu_v02r00b09d06.bin, the address of the FTP server is 20.1.1.11, the user name is hostfile, and the password is drv.

3P@C(config)# download ftp 3P@COS 20.1.1.11 hostfile drv hos_smu_v02r00b09d06.bin

Trying to download file from ftp server, please wait...

3048756 bytes received.

Start saving 3P@COS image...

Done.

 

3P@C(config)# reboot

 

 

 

Start check image and config file, please wait...

 

 

 

--------------------------------------

 

 

 

Current version is V2.0 Release10.4.0.

 

 

 

System version will be V2.0 Release10.4.0 after reboot.

 

 

Config file latest saved on TUE JAN 02 06:31:25 CST 2001 .

 

 

--------------------------------------

 

 

 

Are you sure to reboot the whole system? [Y/N]

 

 

Step 3

After starting the equipment, check whether the upgrade is successful or

 

not.

 

 

 

 

############################################################

 

#

#

 

 

 

#

Welcome to 3P@COS.

#

 

 

#

#

 

 

 

#

Press Return to connect and config this system.

#

 

#

#

 

 

 

############################################################

3P@C Installation Manual

Page 7-11

Reproduction and communication in any form prohibited without the written permission of

SAGEM SA