SAGEM 3P@C
9.2.3. Reset
Reset of the service board needs to be implemented under the following condition:
When some unrecovered faults occur to the system, you can recover the system by resetting the service board.
Reset method for the card:
Reset | Operation | Generation conditions |
mode |
|
|
Soft reset | Use the reboot | Troubleshooting |
| command to reboot the specified |
|
| slot card. |
|
You can implement the
prompt
9.2.4. Replacing Service Board
If the system control board needs to be replaced in the system running process, you should implement the following operation:
Steps | Operation |
|
| Inspection (display of the |
|
|
|
| indicator and screen) |
Step 1 | To confirm the slot of the replaced | The system indicator flashes | ||
| service board, | execute | the | normally. |
| command show version all or |
| ||
| show boardinfo. |
|
| |
Step 2 | Confirm that the service in the |
| ||
| service board | stops, and | the |
|
|
| service should be transferred to |
|
| other cards or devices if |
|
| necessary. |
|
| In the card plugging process, you must wear the |
|
| wrist strap, and guarantee that the other end of the |
|
| wrist strap is connected to the ESD jack of the chassis. On the |
| Note | |
| other hand, you should avoid contacting the circuit with your | |
|
| |
|
| hands. |
Step 3 Unplug the service board:
a)Unplug the cables from all interfaces of the card.
b)Unscrew the screws from the both sides of the card.
c)Pull the extractors on the both sides of the card, and press them outward, thus unplugging the card from the connector of the backboard of the chassis.
d)Hold the front panel to unplug the card from the slot completely.
e)Put the replaced card in the
Step 4 After unplugging the card, you should plug a new service board in the slot of the original service board in 60 seconds
(see the detailed installation steps in the hardware installation part).
3P@C Installation Manual
Page