SAGEM 3P@C
Table
Interface name |
| Quantity | Interface | Description | |
|
|
|
| type |
|
Gigabit optical interface (1000Base- | 2 × 2 | SC | Uplink | ||
SX/LX interface) |
|
|
| interface | |
100M optical interface | 4 × 2 | SC | Uplink | ||
interface) |
|
|
|
| interface |
100M | electrical | interface | (8 + 1) × 2 | Uplink | |
|
|
| interface | ||
ATM interface (155M | 2 × 2 | SC | Uplink | ||
mode ATM interface) |
|
|
| interface | |
Console interface |
| 1 × 2 | Console | ||
|
|
|
|
| interface |
VDSL interface |
| 24 × 14 | European | Subscriber | |
|
|
|
| connector | interfaces |
ADSL interface |
| 32 × 14 | European | Subscriber | |
|
|
|
| connector | interfaces |
For the detailed description of 3P@C 4450E structure, please refer to Chapter 2.
prompt
1.4. Hardware Features
Table
Table
Physical performance | 3P@C 4450E | ||
Dimensions of the 10U chassis | 441.7 mm × 426.5 mm × 389.2 mm | ||
(Height × Width × Depth) |
| ||
Dimensions of the fan module (Height | 44 mm × 434.6 mm × 360.1 mm | ||
× Width × Depth) |
| ||
Dimensions of the air deflector frame | 86.1 mm × 434.6 mm × 371.5 mm | ||
(Height × Width × Depth) |
| ||
| 17 kg when empty (containing a 10U chassis, a backplane, a fan module, a fan mounting | ||
Weight | support and an air deflector frame) | ||
41 kg when fully populated (containing a 10U chassis, a backplane, a fan module, a fan | |||
| |||
| mounting support, an air deflector frame and 16 boards) | ||
Working | Temperature | ||
|
| ||
environment | Humidity | 5% ~ 95%, | |
| |||
Power supply |
| DC: | |
Power consumption | ≤ 1,200 W (1,200 W in full configuration mode) |
3P@C Installation Manual