CHAPTER 9

9. Card Maintenance

9.1. Maintenance for System Control Board

9.1.1. Check

1) Checking running status of the system control board through the indicator

The corresponding status indicator in the front panel of the system control board is used to display the running status of the device, and it plays an important role in the fault analysis and location.

The rough position or cause of the fault can be found through the indicator status, and the indicator status is helpful for the next processing procedure. The indicator does not have the sufficient information, so it is usually used with the coordination of the alarm information analysis.

Check the system running status according to indicator description in the Table 9–1. When finding some exceptional cases, you should take some measures in time.

 

 

 

 

 

The maintenance personnel should pay more attention to the

 

 

 

 

 

study of the indicator meaning, and have the rapid response

 

 

prompt

capability when some faults occur to the system.

 

 

 

 

 

 

 

Table 9-1 Description of LED status of the system control board SMUB

 

 

 

 

 

 

 

 

 

Indicator

Flag

Color

Status

Description

 

 

System

 

 

RUN

Green

Off

The system does not run.

 

 

status

 

 

 

 

Flashing

The system runs normally.

 

 

indicator

ALM

Red

Off

The system runs normally.

 

 

 

 

 

 

 

ON

The system has an alarm. When the

 

 

 

 

 

 

 

 

device starts the self-inspection, this

 

 

 

 

 

 

 

 

indicator will flash once, but it does not

 

 

 

 

 

 

 

 

indicate an alarm.

 

 

Status

 

 

LINK

Green

Constantly

When a stable link is built in the port, the

 

 

indicator

 

 

on

corresponding indicator is constantly on.

 

 

of

the

 

 

Off

No link is in the port.

 

 

Ethernet

ACT

Green

Flashing

Data is being received/transmitted in the

 

 

interface

 

 

 

port

 

 

 

 

 

 

 

Off

Data is not received/transmitted in the

 

 

 

 

 

 

 

 

port

Note: The flashing frequency of the system indicator in the master system control board is faster than that in the standby

system control board. The system indicator of the master

prompt system control board flashes three times per second, and the system indicator of the standby system control board flashes once per second.

3P@C Installation Manual