The following figure shows the parallel and crossed net spacing between Ethernet cable and other pipelines:

Figure 5-2 Parallel and crossed net spacing

L

H

In certain sections, if the Ethernet cable is parallel with the power cable or near interference sources such as

Note electromotor and transformer, and the minimum net spacing between them cannot address requirements, you can use steel tube or metal trough to shield the Ethernet cable.

5.4. Several Forbidden Overhead Cabling Methods

Because outdoor overhead cabling is easy to couple up lightning and damage equipments, it is forbidden to use the outdoor overhead Ethernet cabling, especially use the following cabling methods directly without any protection measures.

Figure 5-3 Direct overhead cabling between two buildings without any protection (1)

Figure 5-4 Direct overhead cabling between two buildings without any protection (2)

Figure 5-5 Direct overhead cabling between two buildings without any protection (3)