SAGEM 3P@C

Step 1 Connecting the Grounding Cable. Connect the grounding cable of the external lightning arrester to the grounding screw stably and check that the length of the tieline is long enough.

Step 2 Use a multimeter to check whether its grounding cable is well connected to the grounding screw and chassis

Step 3 Based on the description of the product instructions, connect the lightning arrester with the equipment network interface through the tieline and with external cables at the same time. Then check whether the network interface LED is operates normally.

Examine the interface identification of the external lightning arrester carefully, do not connect the external cable and

Note tieline to the equipment inversely.

Step 4 Fix the external lightning arrester and bind cables in an orderly fashion.

3P@C Installation Manual

Page 5-5 Reproduction and communication in any form prohibited without the written permission of SAGEM SA