SAGEM 3P@C

Figure 4-43 Uplink optical interface connection

For the descriptions of fibers, please refer to the contents in

Appendix C.

prompt

4.5.Installing the Subscriber Service Cards

The method and procedure for installing the ADUB/ADUC/VDUB are the same as those of the SMUB. Please refer to Section 4.4.3.

4.6.Installing the Dummy Panels

Dummy panels should be installed in the slots where no subscriber service boards or SMUBs are inserted so as to keep the integrity of the air duct of the 10U chassis, ensure the reliable heat dissipation of the system and the good electromagnetic compatibility of the equipment, and meet the dustproof requirements.

To install a dummy panel, take the following steps:

Step 1 Take out a dummy panel, hold both ends of it with both hands, and place it in an empty slot.

Step 2 Press the dummy panel with one hand, and insert screws in the holes on the dummy panel with the other hand.

Step 3 Tighten the screws to end the installation.

The installation is shown in the following figure:

3P@C Installation Manual

Page 4-31

Reproduction and communication in any form prohibited without the written permission of SAGEM SA