SAGEM 3P@C

Figure 11-1 Schematic diagram of pulled handle operation

Alarm indicator

Screw

Press inward

 

Step 5

Pull the fan module outward 10 cm by pulling the pulled handle with

 

your right hand, and make the fan module leave the power supply

 

socket of the interior sub-rack.

Step 6

If you dismount the fan module without cutting off the power supply, you

 

must wait for a minute before the fan stops running completely.

Step 7

Hold the pulled handle of the fan module with your right hand, and pull

 

the fan module out of the sub-rack completely by supporting the bottom

 

of the fan module with your left hand.

Step 8

Put the dismounted fan module in a safe place.

When the fan shelf is dismounted, the fan may still run. Do not contact the fan vane. You should dismount the fan shelf

Warning only when the fan vane stops running completely.

1.1.1.56Install a new fan shelf

If the fan module is replaced on site without cutting off the power supply, you should install the new fan module as soon

Warning as possible when the original one is dismounted. The new fan module should be prepared in advance and put in the

safe place of the installation site.

Installing the fan support: Use screws to attach the rack-mounting ears Step 1 on both sides of the fan support to the cabinet, as shown in the figure

below:

3P@C Installation Manual

Page 11-3

Reproduction and communication in any form prohibited without the written permission of

SAGEM SA