SAGEM 3P@C

Figure 4-8 The connecting boards before combining two cabinets side by side

Figure 4-9 The connecting boards after combining two cabinets side by side

Figure 4-10 Effect after the installation of two combined cabinets

1.1.1.40Insulation test

Set the multimeter to the resistor range to measure the resistance between the bolt of the pressure plate assembly and the cabinet. If the circuit is disconnected, end the installation. Otherwise, it indicates the cabinet is not insulated from the supports. In this case, remove all the pressure plate assemblies to check if any insulation sleeves or pads of the supports are missing or any insulation parts are damaged. Then install the pressure plate assemblies again and repeat the insulation test.

3P@C Installation Manual

Page 4-7Reproduction and communication in any form prohibited without the written permission of SAGEM SA