SAGEM 3P@C

Generally, the screws and nuts have been installed on the four corners of the purchased RTU module, as shown in Figure 4-36. If no screw or nut is installed on the four

corners of the purchased RTU module, then you should first

prompt install the screws and nuts, and then install the RTU on the SMUB.

Figure 4-36 Rear view of the RTU installed with screws and nuts

Installed nut

Rear side of

the RTU

 

4.4.3.Installing the SMUB

Before installing the SMUB, you should first install the uplink interface module and the RTU (optional). To install the SMUB, take the following steps:

Step 1 Cut off the power supply before the installation.

Step 2 Make sure that 3P@C 4450E is well grounded and the operator wears an antistatic wrist strap.

Step 3 Remove the dummy panel installed in the slot of the SMUB by removing the screws.

Step 4 Take out the SMUB, align it with the slot, press the two puller adapters outward with both hands, and push the SMUB along the guide rail into the slot with even force till the SMUB touches the connection socket on the backplane.

Step 5 Press the two puller adapters of the SMUB inward with both hands to plug the SMUB into the connection socket on the backplane. Now the two puller adapters are reset automatically. Tighten the two screws on the puller adapters to fix the SMUB.

Figure 4-37 Installation of the SMUB

Connection

socket

Place one hand on the upper puller

adapter and the other hand on the lower puller adapter of the SMUB, and push the SMUB slightly inward along the guide rail

Guide railBackplane