| Step 5 | Drag the puller adapter to pull out the fan module by 10 cm from | ||
|
|
|
| the chassis so that the fan module is detached from the internal |
|
|
|
| power socket of the chassis. |
| Step 6 | Wait for a minute till the fans fully stop running if you dismount the | ||
|
|
|
| fan module without disconnecting the power supply. |
| Step 7 | Hold the puller adapter of the fan module with the right hand, and | ||
|
|
|
| fully pull out the fan module from the chassis with the left hand |
|
|
|
| holding the bottom of the fan module. |
| Step 8 | Place the removed fan module at a safe place. | ||
|
|
|
|
|
|
|
|
| If you replace the fan module without cutting off its power on |
|
|
|
| site, please install a new fan module as soon as possible |
|
|
|
| after dismounting the fan module. Prepare the new fan |
|
| Note | ||
|
| module in advance and put it away in a safe place on site. |
4.2.3. Installing the Air Deflector Frame
| The air deflector frame should be installed tightly against the | |
| bottom of the fan module. It is forbidden to reserve | |
| unnecessary space between the air deflector frame and the | |
Note | ||
bottom of the fan module. |
Method: Insert the air deflector frame tightly against the bottom of the fan module into the cabinet, and connect the hangers at the two sides of the air deflector frame with the cabinet by using screws, as shown in Figure
Figure
Generally, the air deflector frame delivered has already been mounted with hangers. If not, you can install the hangers
first according to Step 1 above for the installation of the 10U
prompt chassis.
Till now, a general chassis of 3P@C 4450E has been installed. Figure
3P@C Installation Manual
Page | Reproduction and communication in any form prohibited without the written permission of SAGEM SA |