Siemens 112, Tial pressure and flow, Series DS III Hart, PN 32/160 MWP 464/2320 psi Display

Models: P

1 234
Download 234 pages 4.66 Kb
Page 112
Image 112

© Siemens AG 2008

SITRANS P measuring instruments for pressure

Transmitters for gage, absolute and differential pressure, flow and level

DS III series

for differential pressure and flow

 

 

 

 

Selection and Ordering data

 

 

Order No.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SITRANS P pressure transmitters for differen-

 

 

7

M F 4 4

3 3

-

 

 

 

 

 

 

 

tial pressure and flow, Series DS III HART

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

77777

 

-

 

7777

 

 

 

 

 

 

PN 32/160 (MWP 464/2320 psi)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

Measuring cell filling

Measuring cell

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

cleaning

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Silicone oil

Standard

}

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Inert liquid1)

Grease-free

 

 

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Span

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PN 32 (MWP 464 psi)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 ... 20 mbar2)

(0.4015 ... 8.03 inH2O)

}

 

B

 

 

 

 

 

 

 

 

 

 

 

 

 

PN 160 (MWP 2320 psi)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 ... 60 mbar

(0.4015 ... 24.09 inH2O) }

 

C

 

 

 

 

 

 

 

 

 

 

 

 

 

2.5 ... 250 mbar

(1.004 ... 100.4 inH2O)

}

 

D

 

 

 

 

 

 

 

 

 

 

 

 

 

6 ... 600 mbar

(2.409 ... 240.9 inH2O)

}

 

E

 

 

 

 

 

 

 

 

 

 

 

 

 

16 ... 1600 mbar

(6.424 ... 642.4 inH2O)

}

 

F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

50 ... 5000 mbar

(20.08 ... 2008 inH2O)

}

 

G

 

 

 

 

 

 

 

 

 

 

 

 

 

0.3 ... 30 bar

(4.35 ... 435 psi)

}

 

H

 

 

 

 

 

 

 

 

 

 

 

 

 

Wetted parts materials

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(stainless steel process flanges)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Seal diaphragm

Parts of measuring cell

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Stainless steel

Stainless steel

}

 

 

A

 

 

 

 

 

 

 

 

 

 

 

 

Hastelloy

Stainless steel

 

 

 

 

B

 

 

 

 

 

 

 

 

 

 

 

 

Hastelloy

Hastelloy

 

 

 

 

C

 

 

 

 

 

 

 

 

 

 

 

 

Tantalum3)

Tantalum

 

 

 

 

E

 

 

 

 

 

 

 

 

 

 

 

 

Monel3)

Monel

 

 

 

 

H

 

 

 

 

 

 

 

 

 

 

 

 

Gold3)

Gold

 

 

 

 

L

 

 

 

 

 

 

 

 

 

 

 

 

Version for diaphragm seal4) 5)

 

 

 

 

Y

 

 

 

 

 

 

 

 

 

 

 

 

Process connection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Female thread ¼-18 NPT with flange connection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Sealing screw opposite process connection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

- Mounting thread 7/16-20 UNF to EN 61518

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

- Mounting thread M10 to DIN 19213

}

 

0

 

 

 

 

 

 

 

 

 

 

 

(only for replacement needs)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Vent on side of process flange2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

- Mounting thread 7/16-20 UNF to EN 61518

 

 

 

6

 

 

 

 

 

 

 

 

 

 

 

- Mounting thread M10 to DIN 19213

 

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(only for replacement needs)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Non-wetted parts materials

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Process flange screws

Electronics housing

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Stainless steel

Die-cast aluminium

}

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

Stainless steel

Stainless steel precision

 

 

 

3

 

 

 

 

 

 

 

 

 

 

 

casting6)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Version

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Standard version

 

 

 

 

1

 

 

 

 

 

 

 

 

• International version, English label inscriptions, }

 

2

 

 

 

 

 

 

 

 

documentation in 5 languages on CD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Explosion protection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Without

 

 

 

 

 

 

 

 

 

 

A

 

 

 

 

 

 

 

• With ATEX, Type of protection:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

- "Intrinsic safety (EEx ia)"

 

 

 

 

 

 

 

 

 

B

 

 

 

 

 

 

 

- "Explosion-proof (EEx d)"7)

 

 

 

 

 

 

 

 

 

D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

- "Intrinsic safety and explosion-proof

 

 

 

 

 

 

 

 

 

P

 

 

 

 

 

 

 

enclosure (EEx ia + EEx d)"8)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

- "Ex nA/nL (zone 2)"

 

 

 

 

 

 

 

 

 

 

E

 

 

 

 

 

 

 

- "Intrinsic safety, explosion-proof enclosure

}

 

 

 

 

 

 

 

R

 

 

 

 

 

 

 

and dust explosion protection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(EEx ia + EEx d + Zone 1D/2D)"8)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• With FM + CSA, Type of protection:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

- "Intrinsic safety and explosion-proof

 

 

 

 

 

 

 

 

 

N

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C

 

 

 

 

 

 

(is + xp)"7)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Electrical connection / cable entry

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Screwed gland Pg 13.59)

 

 

 

 

 

 

 

 

 

 

A

 

 

 

 

 

 

• Screwed gland M20x1.5

}

 

 

 

 

 

 

 

 

B

 

 

 

 

 

 

• Screwed gland ½-14 NPT

 

 

 

 

 

 

 

 

 

 

C

 

 

 

 

 

 

• Han 7D plug (plastic housing) incl. mating

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D

 

 

 

 

 

 

connector10)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• M12 connectors (metal)10)

 

 

 

 

 

 

 

 

 

 

F

 

 

Selection and Ordering data

Order No.

 

SITRANS P pressure transmitters for differen-

7 M F

4 4 3 3

-

 

 

tial pressure and flow, Series DS III HART

 

 

 

 

 

 

 

 

 

 

77777

 

-

 

7777

 

 

PN 32/160 (MWP 464/2320 psi)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Display

 

 

 

 

 

 

 

 

 

• Without indicator

 

 

 

 

 

 

 

0

 

• Without visible digital indicator (digital indicator }

 

 

 

 

 

 

 

1

 

hidden, setting: mA)

 

 

 

 

 

 

 

 

 

• With visible digital indication

 

 

 

 

 

 

 

6

 

• With customer-specific digital indication (setting

 

 

 

 

 

 

 

7

 

 

 

 

 

 

 

 

 

as specified, Order code "Y21" or required)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

} Available ex stock

Power supply units see "SITRANS I power supply units and isolation amplifiers".

Factory-mounting of shut-off valves and valve manifolds see page 2/142.

Included in delivery of the device:

Brief instructions (Leporello)

CD-ROM with detailed documentation

Sealing plug(s) or sealing screw(s) for the process flanges(s)

1)For oxygen application, add Order code E10.

2)Not suitable for connection of remote seal. Position of the top vent valve in the process flanges (see dimensional drawing).

3)Only together with max. spans 250, 1600, 5000 and 30000 mbar (100.4, 240.9, 2008 inH2O and 435 psi)

4)When the manufacture’s certificate M (calibration certificate) has to be ordered for transmitters with diaphragm seals, it is recommended only to order this certificate exclusively with the diaphragm seals. The measuring accuracy of the total combination is certified here.

5)Whe the acceptance test certificate 3.1 for transmitters with direct-con- nected diaphragm seals is ordered, this certificate must also be ordered with the corresponding seals.

6)Not together with Electrical connection „Screwed gland Pg 13.5“ and „Han7D plug“.

7)Without cable gland, with blanking plug

8)With enclosed cable gland EEx ia and blanking plug

9)Not together with type of protection "Explosion-proof" and and type of protection "Ex nA".

10)Cannot be used together with the following types of protection: "Explosion-proof" and "Intrinsic safety and explosion-proof"

2/112

Siemens FI 01 · 2009

Page 112
Image 112
Siemens 112, Tial pressure and flow, Series DS III Hart, PN 32/160 MWP 464/2320 psi Measuring cell filling Cleaning