Siemens P Transmitters for gage pressure for the paper industry, To EN 61326 and Namur NE Munity

Models: P

1 234
Download 234 pages 4.66 Kb
Page 53
Image 53

 

© Siemens AG 2008

 

 

 

 

SITRANS P measuring instruments for pressure

 

Transmitters for gage pressure for the paper industry

 

 

 

DS III series with PMC connection

 

 

 

 

 

 

 

SITRANS P, DS III series for gage pressure with PMC connection for the paper industry

 

 

 

 

 

 

 

 

 

HART

PROFIBUS PA or FOUNDATION Fieldbus

 

 

 

 

 

 

 

Rated operating conditions

 

 

 

 

 

 

Degree of protection (to EN 60529)

IP65, IP68, NEMA X, enclosure cleaning, resistant to lyes, steam to 150° C (302 °F)

 

2

Process temperature

-20 ... +100 °C (-4 ... +212 °F)

 

 

 

 

 

 

Ambient conditions

 

 

 

 

 

 

• Ambient temperature

-20 ... +85 °C (-4 ... +185 °F)

 

 

 

 

• Storage temperature

-50 ... +85 °C (-58 ... +185 °F)

 

 

 

 

• Climatic class

 

 

 

 

 

 

- Condensation

Permissible

 

 

 

 

• Electromagnetic compatibility

 

 

 

 

 

 

- Emitted interference and interference im-

To EN 61326 and NAMUR NE 21

 

 

 

 

munity

 

 

 

 

 

 

 

 

 

 

 

 

 

Design

 

 

 

 

 

 

Weight (without options)

1.5 kg (3.3 lb)

 

 

 

 

Housing material

Poor in copper die-cast aluminium, GD-AlSi12 or stainless steel precision casting, mat. No. 1.4408

Wetted parts materials

Stainless steel

 

 

 

 

• Gasket (standard)

PTFE flat gasket

 

 

 

 

O-ring (minibolt)

FPM (Viton) or optionally: FFPM or NBR

 

 

 

 

Measuring cell filling

Silicone oil or inert filling liquid

 

 

 

 

Process connection (standard)

Front-flush, 1½", PMC Standard design

 

 

 

 

Process connection (minibolt)

Front-flush, 1", minibolt design

 

 

 

 

 

 

 

 

 

Power supply UH

 

 

Supplied through bus

Terminal voltage on transmitter

10.5 ... 45 V DC

-

 

 

 

 

10.5 ... 30 V DC in intrinsically-safe mode

 

 

 

 

Separate 24 V power supply necessary

-

 

No

Bus voltage

 

 

 

 

 

 

 

 

 

 

 

 

• Not Ex

-

 

9 ... 32 V

 

• With intrinsically-safe operation

-

 

9 ... 24 V

Current consumption

 

 

 

 

 

 

 

 

 

 

 

 

• Basic current (max.)

-

 

12.5 mA

 

• Startup current basic current

-

 

Yes

• Max. current in event of fault

-

 

15.5 mA

Fault disconnection electronics (FDE) avail-

-

 

Yes

able

 

 

 

 

 

 

 

 

 

 

 

 

 

Certificate and approvals

 

 

 

 

 

 

Classification according to pressure equip-

For gases of fluid group 1 and liquids of fluid group 1; complies with requirements of Article 3, para-

ment directive (DRGL 97/23/EC)

graph 3 (sound engineering practice)

 

 

 

 

 

 

 

 

 

 

 

Siemens FI 01 · 2009

2/53

Page 53
Image 53
Siemens P technical specifications Transmitters for gage pressure for the paper industry, To EN 61326 and Namur NE Munity