Siemens P technical specifications 142, Selection and Ordering data

Models: P

1 234
Download 234 pages 4.66 Kb
Page 142
Image 142

© Siemens AG 2008

SITRANS P measuring instruments for pressure

SITRANS P Accessories

Factory-mounting of valve manifolds on

SITRANS P transmitters

 

 

 

 

The 7MF9011-4FA valve manifolds are sealed with PTFE sealing

 

Overview

 

tape between the transmitter and the valve manifold.

 

 

 

 

 

 

SITRANS P transmitters

The 7MF9411-5BA and 7MF9411-5CA valve manifolds are

 

 

• P300 for relative and absolute pressure,

sealed with PTFE sealing rings between the transmitter and the

 

 

• DS III for relative and absolute pressure (both designs) and

valve manifold.

2

 

 

 

 

• DS III for differential pressure

Once installed, the complete unit is checked under pressure for

 

leaks and is certified leak-proof with a factory certificate to

 

 

can be delivered factory-fitted with the following valve manifolds:

 

 

EN 10204 - 2.2.

 

 

7MF9011-4EA and 7MF9011-4FA valve manifolds for relative

All valve manifolds should preferably be secured with the re-

 

 

pressure and absolute pressure transmitters

 

 

spective mounting brackets. The transmitters are mounted on

 

 

7MF9411-5BA and 7MF9411-5CA valve manifolds for abso-

 

 

the valve manifold and not on the unit itself.

 

 

lute pressure and differential pressure transmitters

If you order a mounting bracket when choosing the option "Fac-

 

 

 

 

 

 

 

 

tory mounting of valve manifolds", you will receive a mounting

 

Design

 

bracket for the valve manifold instead of a bracket for mounting

 

 

The 7MF9011-4EA valve manifolds are sealed with gaskets

the transmitter.

 

 

 

 

 

made of PTFE between transmitter and the valve manifold as

If you order an acceptance test certificate 3.1 to EN10204 when

 

 

standard. Soft iron, stainless steel and copper gaskets are also

choosing the option "Factory mounting of valve manifolds", a

 

 

available for sealing purposes if preferred.

separate certificate is provided for the transmitters and the valve

manifolds respectively.

Selection and Ordering data

7MF9011-4FA valve block on

relative and absolute pressure transmitters

 

Add -Z to the Order No. of the transmitter

Order

 

and add order codes.

code

 

 

 

 

SITRANS P DSIII

T03

 

7MF403.-...1.-..., 7MF423.-...1.-... and

 

 

SITRANS P300

 

 

7MF802.-...1.-...

 

 

With process connection female thread

 

 

½-14 NPT in-sealed with PTFE sealing

 

 

strip

 

 

Delivery incl. high-pressure test certified

 

 

by factory certificate to EN10204-2.2

 

7MF9011-4EA valve block on

 

relative and absolute pressure transmitters

 

 

 

 

 

Add -Z to the Order No. of the transmitter

Order

 

and add order codes.

code

 

 

 

 

SITRANS P DSIII

T02

 

7MF403.-...0.-..., 7MF423.-...0.-... and

 

 

SITRANS P300

 

 

7MF802.-...0.-...

 

 

with process connection collar G1/2 A to

 

 

EN837-1 with gasket made of PTFE

 

 

between valve manifold and transmitter

 

 

Alternative sealing material:

 

 

• soft iron

A70

 

• stainless steel, Mat. No. 14571

 

 

A71

 

• copper

A72

 

Delivery incl. high-pressure test certified

 

 

by factory certificate to EN10204-2.2

 

 

Further designs:

 

 

Delivery includes mounting brackets and

 

 

A02

 

mounting clips made of stainless steel

 

 

(instead of the mounting bracket sup-

 

 

plied with the transmitter)

 

 

Supplied acceptance test certificate to

C12

 

EN 10204- 3.1 for transmitters and

 

 

mounted valve manifold

 

 

Oil and grease-free cleaning for oxygen

E10

 

operation

 

 

 

 

7MF9411-5BA valve manifold on

absolute and differential pressure transmitters

 

Add -Z to the Order No. of the transmitter

Order

 

and add order codes.

code

 

 

 

 

SITRANS P DSIII

 

 

7MF433.-…, 7MF443.-… and

 

 

7MF453.-…1)

 

 

mounted with gaskets made of PTFE and

 

 

screws made of

 

 

• chromized steel

 

 

U01

 

• stainless steel

U02

 

Delivery incl. high-pressure test certified

 

 

by factory certificate to EN10204-2.2

 

 

 

 

7MF9411-5CA valve manifold on differential pressure transmitters

 

Add -Z to the Order No. of the transmitter

Order

 

and add order codes.

code

 

 

 

 

SITRANS P DSIII

 

 

7MF443.-... und 7MF453.-…1)

 

 

mounted with gaskets made of PTFE and

 

 

screws made of

 

 

• chromized steel

 

 

U03

 

• stainless steel

U04

 

Delivery incl. high-pressure test certified

 

 

by factory certificate to EN10204-2.2

 

 

Further designs:

 

 

Delivery includes mounting bracket and

 

 

mounting clips made of

 

 

• steel

 

 

A01

 

• stainless steel

A02

 

(instead of the mounting bracket sup-

 

 

plied with the transmitter)

 

 

Supplied acceptance test certificate to

C12

 

EN10204-3.1 for transmitters and

 

 

mounted valve manifold

 

 

Oil and grease-free cleaning for oxygen

E10

 

operation

 

 

 

 

1)For 7MF453.-... transmitters, you require a 7/10-20 UNF connection thread in the process flange.

2/142

Siemens FI 01 · 2009

Page 142
Image 142
Siemens P technical specifications 142, Selection and Ordering data