Siemens P C11 Bration to IEC 60770-2 Acceptance test certificate2 C12, E55 China

Models: P

1 234
Download 234 pages 4.66 Kb
Page 95
Image 95

© Siemens AG 2008

SITRANS P measuring instruments for pressure

Transmitters for gage, absolute and differential pressure, flow and level

DS III series for absolute pressure (from gage pressure series)

Selection and Ordering data

Order code

 

 

Further designs

 

HART

PA

FF

Add "-Z" to Order No. and specify Order

 

 

 

 

 

 

 

 

code.

 

 

 

 

 

 

 

 

 

Pressure transmitter with mounting

 

 

 

 

bracket made of:

 

 

 

 

• Steel

A01

￿

￿

￿

• Stainless steel

A02

￿

￿

￿

Plug

 

 

 

 

 

 

 

 

• Han 7D (metal, gray)

A30

￿

 

 

 

 

• Han 8U (instead of Han 7D)

A31

￿

 

 

Cable sockets for M12 connectors (metal)

A50

￿

￿

￿

Rating plate inscription

 

 

 

 

 

 

 

 

(instead of German)

 

 

 

 

• English

B11

￿

￿

￿

• French

B12

￿

￿

￿

• Spanish

B13

￿

￿

￿

• Italian

 

 

 

 

B14

￿

￿

￿

English rating plate

B21

￿

￿

￿

Pressure units in inH2O or psi

 

 

 

 

 

 

 

 

Quality inspection certificate (Factory cali-

C11

￿

￿

￿

bration) to IEC 60770-2 1)

 

 

 

 

Acceptance test certificate2)

C12

￿

￿

￿

To EN 10204-3.1

 

 

 

 

 

 

 

 

Factory certificate

C14

 

 

 

￿

￿

￿

To EN 10204-2.2

 

 

 

 

 

 

 

 

 

 

 

 

 

"Functional Safety (SIL)" certificate

C20

￿

 

 

"PROFIsafe" certificate and protocol

C21

 

￿

 

 

 

 

 

 

Setting of upper limit of output signal to

D05

￿

 

 

22.0 mA

 

 

 

 

Manufacturer's declaration acc. to NACE

D07

￿

￿

￿

Type of protection IP68

D12

￿

￿

￿

(not together with Han 7D / Han 8U plug,

 

 

 

 

 

 

 

 

Pg 13.5 screwed gland)

 

 

 

 

Digital indicator alongside the input keys

D27

 

 

 

￿

￿

￿

(only together with the devices 7MF4233-

 

 

 

 

 

 

 

 

....0-.A.6 or -.A.7-Z, Y21 or Y22 + Y01).

 

 

 

 

 

 

 

 

 

Supplied with oval flange

D37

￿

￿

￿

(1 item), PTFE packing and screws in thread

 

 

 

 

 

 

 

 

of oval flange

 

 

 

 

Use in or on zone 1D/2D

E01

 

 

 

￿

￿

￿

(only together with type of protection "Intrinsic

 

 

 

 

 

 

 

 

safety (EEx ia)")

 

 

 

 

Use on zone 0

E02

 

 

 

￿

￿

￿

(only together with type of protection "Intrinsic

 

 

 

 

 

 

 

 

safety (EEx ia)")

 

 

 

 

Oxygen application

E10

 

 

 

￿

￿

￿

(max. 120 bar a (1740 psi a) at 60 °C (140 °F)

 

 

 

 

 

 

 

 

with oxygen measurement and inert liquid)

 

 

 

 

Explosion-proof "Intrinsic safety" to

E25

 

 

 

￿

￿

￿

INMETRO (Brazil)

 

 

 

 

(only for transmitter 7MF4...-.....-.B..)

 

 

 

 

 

 

 

 

 

 

 

 

 

Explosion-proof "Intrinsic safety" to NEPSI

E55

￿

￿

￿

(China)

 

 

 

 

(only for transmitter 7MF4...-.....-.B..)

 

 

 

 

 

 

 

 

Explosion protection "Explosion-proof" to

E56

 

 

 

￿

￿

￿

NEPSI (China)

 

 

 

 

(only for transmitter 7MF4...-.....-.D..)

 

 

 

 

 

 

 

 

Explosion-proof "Zone 2" to NEPSI (China)

E57

 

 

 

￿

￿

￿

(only for transmitter 7MF4...-.....-.E..)

 

 

 

 

 

 

 

 

 

 

 

 

 

Selection and Ordering data

 

 

Order code

 

 

 

 

Additional data

 

 

 

 

 

 

HART

PA

FF

 

 

Add "-Z" to Order No. and specify Order

 

 

 

 

 

 

 

 

 

 

 

 

code.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Measuring range to be set

 

 

Y01

￿

 

 

 

2

Specify in plain text (max. 5 digits):

 

 

 

 

 

 

Y01: ...

up to ... mbar, bar, kPa, MPa, psi

 

 

 

 

 

 

Measuring point number (TAG No.)

Y15

 

 

 

 

 

￿

￿

￿

 

 

Max. 16 characters, specify in plain text:

 

 

 

 

 

 

Y15:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Measuring point text

 

 

 

 

Y16

￿

￿

￿

 

Max. 27 characters, specify in plain text:

 

 

 

 

 

 

Y16:

 

 

 

 

 

 

 

 

 

 

 

Entry of HART address (TAG)

 

 

Y17

￿

 

 

 

 

 

 

 

 

 

 

Max. 8 characters, specify in plain text:

 

 

 

 

 

 

Y17:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Setting of pressure indication in pressure

Y21

￿

￿

￿

 

units

 

 

 

 

 

 

 

 

 

 

 

 

Specify in plain text (standard setting: mA):

 

 

 

 

 

 

Y21: mbar, bar, kPa, MPa, psi, ...

 

 

 

 

 

 

 

 

Note:

 

 

 

 

 

 

 

 

 

 

 

 

The following pressure units can be selected:

 

 

 

 

 

 

bar, mbar, mm H

O*), inH

2

O*), ftH

2

O*),

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

mmHG, inHG, psi, Pa, kPa, MPa, g/cm2,

 

 

 

 

 

 

kg/cm2, Torr, ATM oder %

 

 

 

 

 

 

 

 

 

*) ref. temperature 20 °C

 

 

 

 

 

 

 

 

 

 

Setting of pressure indication in

 

Y22 +

 

 

 

 

 

￿

￿

￿

 

non-pressure units

 

 

 

 

Y01

 

 

 

 

 

Specify in plain text:

 

 

 

 

 

 

 

 

 

 

Y22:

up to

l/min, m3/h, m, USgpm, ...

 

 

 

 

 

 

(specification of measuring range in pressure

 

 

 

 

 

 

units "Y01" is essential, unit with

 

 

 

 

 

 

 

 

max. 5 characters)

 

 

 

 

 

 

 

 

 

 

Preset bus address

 

 

 

 

Y25

 

￿

 

 

 

 

 

 

 

 

 

 

 

(possible between 1 and 126)

 

 

 

 

 

 

 

 

Specify in plain text:

 

 

 

 

 

 

 

 

 

 

Y25:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Only "Y01", "Y21", "Y22", "Y25" and "D05" can be factory preset

￿= available

1)When the manufacture’s certificate M (calibration certificate) has to be ordered for transmitters with diaphragm seals, it is recommended only to order this certificate exclusively with the diaphragm seals. The measuring accuracy of the total combination is certified here.

2)Whe the acceptance test certificate 3.1 for transmitters with direct-con- nected diaphragm seals is ordered, this certificate must also be ordered with the corresponding seals.

Siemens FI 01 · 2009

2/95

Page 95
Image 95
Siemens P technical specifications C11 Bration to IEC 60770-2 Acceptance test certificate2 C12, E55 China