© Siemens AG 2008

SITRANS P measuring instruments for pressure

Transmitters for gage, absolute and differential pressure, flow and level

DS III series for absolute pressure (from differential pressure series)

Selection and Ordering data

Order No.

 

SITRANS P pressure transmitters for absolute F)

7 M F 4 3 3 3 -

 

pressure, from the differential pressure,

 

77777 -

7777

 

series DS III HART

 

 

 

 

 

 

 

2

Measuring cell filling

Measuring cell

 

 

 

 

cleaning

 

 

 

Silicone oil

Standard

 

1

 

 

Inert liquid1)

Grease-free

 

3

 

 

Span

 

 

 

 

 

8.3 ... 250 mbar a

(0.12 ... 3.63 psi a)

E)

D

 

 

43 ... 1300 mbar a

(0.62 ... 18.9 psi a)

E)

F

 

 

0.16 ... 5 bar a

(2.32 ... 72.5 psi a)

E)

G

 

 

1 ... 30 bar a

(14.5 ... 435 psi a)

 

H

 

 

5.3 ... 100 bar a

(76.9 ... 1450 psi a)

 

K E

 

 

Wetted parts materials

 

 

 

 

 

Seal diaphragm

Parts of measuring cell

 

 

 

 

Stainless steel

Stainless steel

 

A

 

 

Hastelloy

Stainless steel

 

B

 

 

Hastelloy

Hastelloy

 

C

 

 

Tantalum

Tantalum

 

E

 

 

Monel

Monel

E)

H

 

 

Gold

Gold

 

L

 

 

Version for diaphragm seal2)3)4)

 

Y

 

 

Process connection

 

 

 

 

 

Female thread ¼-18 NPT with flange connection

 

 

 

 

• Sealing screw opposite process connection

 

 

 

 

- Mounting thread 7/16-20 UNF to EN 61518

 

2

 

 

- Mounting thread M10 to DIN 19213

 

0

 

 

(only for replacement needs)

 

 

 

 

• Vent on side of process flange5)

 

 

 

 

- Mounting thread 7/16-20 UNF to EN 61518

 

6

 

 

- Mounting thread M10 to DIN 19213

 

4

 

 

(only for replacement needs)

 

 

 

 

Non-wetted parts materials

 

 

 

 

Process flange screws

Electronics housing

 

 

 

 

Stainless steel

Die-cast aluminium

 

2

 

 

Stainless steel

Stainless steel precision

 

3

 

 

 

casting6)

 

 

 

 

Version

 

 

 

 

 

• Standard version

 

 

 

1

 

• International version, English label inscriptions,

 

 

2

 

documentation in 5 languages on CD

 

 

 

 

Explosion protection

 

 

 

 

 

• Without

 

 

 

A

 

• With ATEX, Type of protection:

 

 

 

 

- "Intrinsic safety (EEx ia)"

 

 

B

 

- "Explosion-proof (EEx d)"7)

 

 

D

 

- "Intrinsic safety and explosion-proof enclosure

 

 

P

 

(EEx ia + EEx d)" 8)

 

 

 

 

 

- "Ex nA/nL (zone 2)"

 

 

 

E

 

- "Intrinsic safety, explosion-proof enclosure and

 

 

R

 

dust explosion protection (EEx ia + EEx d +

 

 

 

 

Zone 1D/2D)"8)

 

 

 

 

 

• With FM + CSA, Type of protection:

 

 

 

 

- "Intrinsic safety and explosion-proof

 

 

N C

 

(is + xp)"7)

 

 

 

 

Electrical connection / cable entry

 

 

 

• Screwed gland Pg 13.59)

 

 

 

 

A

• Screwed gland M20x1.5

 

 

B

• Screwed gland ½-14 NPT

 

 

 

 

 

C

• Han 7D plug (plastic housing) incl. mating

 

 

D

connector9)

 

 

 

• Plug M12 (metal)10)

 

 

F

Selection and Ordering data

Order No.

 

SITRANS P pressure transmitters for absolute F)

7 M F

4 3 3 3

-

 

 

pressure, from the differential pressure,

 

 

 

 

 

 

 

 

 

 

77777

 

-

 

7777

 

 

series DS III HART

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Display

 

 

 

 

 

 

 

 

 

• Without indicator

 

 

 

 

 

 

 

0

 

• Without visible digital indicator (digital indicator }

 

 

 

 

 

 

 

1

 

hidden, setting: mA)

 

 

 

 

 

 

 

 

 

• With visible digital indicator

 

 

 

 

 

 

 

6

 

• With customer-specific digital indicator (setting

 

 

 

 

 

 

 

7

 

 

 

 

 

 

 

 

 

as specified, Order code "Y21" or required)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power supply units see "SITRANS I power supply units and isolation amplifiers".

Factory-mounting of shut-off valves and valve manifolds see page 2/142.

Included in delivery of the device:

Brief instructions (Leporello)

CD-ROM with detailed documentation

Sealing plug(s) or sealing screw(s) for the process flanges(s)

1)For oxygen applications, add Order code E10.

2)Version 7MF4333-1DY... only up to max. span 200 mbar a (2.9 psi a).

3)When the manufacture’s certificate M (calibration certificate) has to be ordered for transmitters with diaphragm seals, it is recommended only to order this certificate exclusively with the diaphragm seals. The measuring accuracy of the total combination is certified here.

4)Whe the acceptance test certificate 3.1 for transmitters with direct-con- nected diaphragm seals is ordered, this certificate must also be ordered with the corresponding seals.

5)Not for span "5.3 ... 100 bar a (76.9 ... 1450 psi a)". Position of the top vent valve in the process flange (see dimensional drawing).

6)Not together with Electrical connection „Screwed gland Pg 13.5“ and „Han7D plug“.

7)Without cable gland, with blanking plug

8)With enclosed cable gland EEx ia and blanking plug

9)Not together with type of protection "Explosion-proof" and and type of protection "Ex nA".

10)Not together with types of protection "Explosion-proof" or "Intrinsic safety and explosion-proof"

E)Combinations of the versions marked with E) are subject to the export regulations AL: 2B230, ECCN: N.

F)Subject to export regulations AL: 9I999, ECCN: N.

2/102

Siemens FI 01 · 2009

Page 102
Image 102
Siemens technical specifications 102, Pressure, from the differential pressure, Casting6, EEx ia + EEx d Ex nA/nL zone