SITRANS P measuring instruments for pressure

Diaphragm seals of sandwich design

For gage, absolute, differential pressure and flow with flexible capillary

 

 

Selection and Ordering data

Order No. Ord.code

 

 

 

Selection and Ordering data

Order No. Ord.code

 

 

 

 

 

 

 

 

 

 

 

Diaphragm seal

 

 

 

 

Diaphragm seal

 

 

 

 

 

 

 

 

 

 

Sandwich-type design, with flexible capillary connected to a SITRANS P transmitter (order separately):

for pressure 7MF4037 and 7MF4237 together D) 7 M F 4 9 0 0 -

 

with Order code "V01" (vacuum-proof design)

 

 

and 7MF80271);

 

 

 

Scope of delivery (1 off)

 

 

for absolute pressure 7MF4337;

D) 7 M F 4 9 0 1 -

 

Scope of delivery (1 off)

 

 

for differential pressure and flow 7MF443 7;

D) 7 M F 4 9 0 3 -

 

scope of delivery 2 off

 

 

 

 

 

1 7777 - 7B

777

Nominal diameter and nominal pressure

 

 

• DN 50

PN 16 ... 100

A

 

(recommended only for pressure transmitters

 

 

for pressure)

 

 

 

• DN 80

PN 16 ... 100

B

 

• DN 100

PN 16 ... 100

C

 

• DN 125

PN 16 ... 100

D

 

• 2 inch

Class 150 ... 2500

E

 

(recommended only for pressure transmitters

 

 

for pressure)

 

 

 

• 3 inch

Class 150 ... 2500

H

 

• 4 inch

Class 150 ... 2500

L

 

• 5 inch

Class 150 ... 2500

N

 

Smooth sealing face to EN 1092-1, form B1 or

 

 

to ASME B16.5 RF 125 ... 250 AA

 

 

Other version

 

Z

J 1 Y

Add Order code and plain text:

 

 

Nominal diameter: ...; Nominal pressure: ...

 

 

Sealing face: see "Technical data"

 

 

Wetted parts materials

 

 

• Stainless steel 316L

 

 

 

- without foil

 

A

 

- with PTFE coating

 

E 0

 

- with ECTFE coating2)

F

 

- with PFA coating

 

D

 

• Monel 400, mat. No. 2.4360

G

 

• Hastelloy C276, mat. No. 2.4819

J

 

• Hastelloy C4, mat. No. 2.4610

U

 

• Tantalum

 

K

 

Other version

 

Z

K 1 Y

Add Order code and plain text:

 

 

Wetted parts materials: ...

 

 

Tube length

 

 

 

• without tube

 

0

 

Other version:

 

9

L 1 Y

Add Order code and plain text:

 

 

Tube length: ...

 

 

 

Filling liquid

 

 

 

• Silicone oil M5

 

1

 

• Silicone oil M50

 

2

 

High-temperature oil

 

3

 

• Halocarbon oil (for measuring O2)

4

 

• Glycerin/water3)

 

6

 

• Food oil (FDA listed)l

 

7

 

Other version

 

9

M 1 Y

Add Order code and plain text:

 

 

Filling liquid: ...

 

 

 

Sandwich-type design, with flexible capillary connected to a SITRANS P transmitter (order separately):

 

for pressure 7MF4037 and 7MF4237 together

D)

7

M F 4

9

0 0 -

 

 

2

 

with Order code "V01" (vacuum-proof design)

 

 

 

 

and 7MF80271);

 

 

 

 

 

 

 

 

 

 

 

 

 

Scope of delivery (1 off)

 

 

 

 

 

 

 

 

 

 

 

 

 

for absolute pressure 7MF433 7;

D)

7

M

F 4

9

0

1 -

 

 

 

 

Scope of delivery (1 off)

 

 

 

 

 

 

 

 

 

 

 

 

 

for differential pressure and flow 7MF4437;

D)

7

M

F 4

9

0

3 -

 

 

 

 

scope of delivery 2 off

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

-

 

B

 

 

 

 

 

 

 

 

7777

 

7

777

 

 

Length of capillary2)

 

 

 

 

 

 

 

 

 

 

 

 

 

• 1.0 m

(3.28 ft)

 

 

2

 

 

 

 

 

• 1.6 m

(5.25 ft)

 

 

3

 

 

 

 

 

• 2.5 m

(8.20 ft)

 

 

4

 

 

 

 

 

• 4.0 m

(13.1 ft)

 

 

5

 

 

 

 

 

• 6.0 m

(19.7 ft)

 

 

6

 

 

 

 

 

• 8.0 m

(26.25 ft)

 

 

7

 

 

 

 

 

• 10.0 m

(32.8 ft)

 

 

8

 

 

 

 

 

Other version

 

 

 

9

 

 

 

 

 

 

N 1

Y

 

Add Order code and plain text:

 

 

 

 

 

 

 

 

 

 

 

 

Length of capillary: ...

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1)With 7MF8027 and the measuring cells Q, S, T and U also order the vacuum-tight version.

2)Max. capillary length, see section "Technical description".

D) Subject to export regulations AL: N, ECCN: EAR99H.

Selection and Ordering data

Order code

Further designs

 

 

Please add "-Z" to Order No. and specify Order code.

 

 

 

 

 

Spark arrestor

 

 

With spark arrestor for mounting on zone 0 (including

 

 

documentation)

 

 

• Pressure and absolute pressure

A01

 

• for differential pressure transmitters

A02

 

Quality inspection certificate (Factory calibration) to

C11

 

IEC 60770-2

 

 

 

 

 

Acceptance test certificate

C12

 

to EN 10204, section 3.1

 

 

 

 

Vacuum-proof design

 

 

for use in low-pressure range for transmitters for

 

 

• Pressure

 

V01

 

• For differential pressure transmitters

V03

 

Calculation of span of associated pressure

Y05

transmitter

 

 

Enclose filled-in questionnaire with order

1)With 7MF8027 and the measuring cells Q, S, T and U also order the vac- uum-tight version.

2)For vacuum on request

3)Not suitable for use in low-pressure range.

Siemens FI 01 · 2009

2/159

Page 159
Image 159
Siemens P technical specifications 159