SITRANS P measuring instruments for pressure

Transmitters for gage, absolute and differential pressure, flow and level

DS III series for absolute pressure (from differential pressure series)

 

 

Selection and Ordering data

Order No.

 

 

 

Selection and Ordering data

Order No.

 

 

 

 

 

 

 

 

 

SITRANS P pressure transmitters for absolute pressure (from the differential pressure series)

SITRANS P pressure transmitters for absolute pressure (from the differential pressure series)

DS III PA series (PROFIBUS PA)

F)

7 M F 4 3 3 4 -

DS III FF series (FOUNDATION Fieldbus)

F)

7 M F 4 3 3 5 -

 

 

 

77777 -

7777

Measuring cell filling

Measuring cell

 

 

 

 

cleaning

 

 

 

Silicone oil

Standard

 

1

 

Inert liquid1)

Grease-free

 

3

 

Nominal measuring range

 

 

 

250 mbar a

(3.63 psi a)

E)

D

 

1300 mbar a

(18.9 psi a)

E)

F

 

5 bar a

(72.5 psi a)

E)

G

 

30 bar a

(435 psi a)

 

H

 

100 bar a

(1450 psi a)

 

K E

 

Wetted parts materials

 

 

 

 

Seal diaphragm

Parts of measuring cell

 

 

 

 

 

Stainless steel

Stainless steel

 

A

 

Hastelloy

Stainless steel

 

B

 

Hastelloy

Hastelloy

 

C

 

Tantalum

Tantalum

 

E

 

Monel

Monel

E)

H

 

Gold

Gold

 

L

 

Version as diaphragm seal2)3)4)

 

Y

 

Process connection

 

 

 

 

 

 

Female thread ¼-18 NPT with flange connection

 

 

 

 

 

• Sealing screw opposite process connection

 

 

 

 

 

- Mounting thread 7/16-20 UNF to EN 61518

 

 

2

 

 

- Mounting thread M10 to DIN 19213

 

 

0

 

 

(only for replacement needs)

 

 

 

 

 

• Vent on side of process flange5)

 

 

 

 

 

- Mounting thread 7/16-20 UNF to EN 61518

 

 

6

 

 

- Mounting thread M10 to DIN 19213

 

 

4

 

 

(only for replacement needs)

 

 

 

 

 

Non-wetted parts materials

 

 

 

 

 

Process flange screws

Electronics housing

 

 

 

 

 

 

 

 

 

 

 

Stainless steel

Die-cast aluminium

 

 

 

2

 

Stainless steel

Stainless steel precision

 

 

 

 

 

 

 

3

 

 

casting

 

 

 

 

 

 

 

 

 

 

 

 

Version

 

 

 

 

 

• Standard version

1

 

 

• International version, English label inscriptions,

 

 

 

 

 

 

2

 

documentation in 5 languages on CD

 

 

 

 

 

Explosion protection

 

 

 

 

 

• Without

 

 

 

A

 

• With ATEX, Type of protection:

 

 

 

 

 

- "Intrinsic safety (EEx ia)"

 

 

 

B

 

- "Explosion-proof (EEx d)"6)

 

 

 

D

 

- "Intrinsic safety and explosion-proof enclosure

 

 

 

P

 

(EEx ia + EEx d)"7)

 

 

 

 

 

- "Ex nA/nL (zone 2)"

 

 

 

E

 

- "Intrinsic safety, explosion-proof enclosure and

 

 

 

R

 

dust explosion protection (EEx ia + EEx d +

 

 

 

 

 

Zone 1D/2D)"7) (not for DS III FF)

 

 

 

 

 

• With FM + CSA, Type of protection:

 

 

 

 

 

 

 

 

 

 

- "Intrinsic safety and explosion-proof

 

 

 

N

C

(is + xp)"6)

 

 

 

 

 

Electrical connection / cable entry

 

 

 

 

 

• Screwed gland M20x1.5

 

 

 

 

B

• Screwed gland ½-14 NPT

 

 

 

 

 

 

 

 

 

C

• M12 Connector (metall)8)

 

 

 

 

F

DS III PA series (PROFIBUS PA)

F)

7

M F

4

3 3 4

-

 

 

 

DS III FF series (FOUNDATION Fieldbus)

F)

7

M F

4

3 3 5

-

 

 

2

 

 

 

77777

 

-

 

7777

 

 

 

Display

 

 

 

 

 

 

 

 

 

 

 

 

• Without indicator

 

 

 

 

 

 

 

 

0

 

 

 

• Without visible digital indicator (digital indicator }

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

hidden, setting: mA)

 

 

 

 

 

 

 

 

 

 

 

 

• With visible digital indicator

 

 

 

 

 

 

 

 

6

 

 

 

• With customer-specific digital indicator (setting

 

 

 

 

 

 

 

 

7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

as specified, Order code "Y21" or required)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Factory-mounting of shut-off valves and valve manifolds see page 2/142.

Included in delivery of the device:

Brief instructions (Leporello)

CD-ROM with detailed documentation

Sealing plug(s) or sealing screw(s) for the process flanges(s)

1)For oxygen application, add Order code E10.

2)Version 7MF4334-1DY... only up to max. span 200 mbar a (2.9 psi a).

3)When the manufacture’s certificate M (calibration certificate) has to be ordered for transmitters with diaphragm seals, it is recommended only to order this certificate exclusively with the diaphragm seals. The measuring accuracy of the total combination is certified here.

4)Whe the acceptance test certificate 3.1 for transmitters with direct-con- nected diaphragm seals is ordered, this certificate must also be ordered with the corresponding seals.

5)Not for nominal measuring range 100 bar a (1450 psi a). Position of the top vent valve in the process flange (see dimensional drawing).

6)Without cable gland, with blanking plug

7)With enclosed cable gland EEx ia and blanking plug

8)Cannot be used together with the following types of protection: "Explosion-proof" and "Intrinsic safety and explosion-proof".

E)Combinations of the versions marked with E) are subject to the export regulations AL: 2B230, ECCN: N.

F)Subject to export regulations AL: 9I999, ECCN: N.