SITRANS P measuring instruments for pressure

SITRANS P Accessories

Supplementary electronics for 4-wire connection

Overview

2

Structural design

 

Dimensions (W x H x D) in mm

80 x 120 x 60 (3.15 x 4.72 x 2.36)

(inch)

 

Electrical connection

Screw terminals (Pg 13.5 cable

 

inlet) or Han 7D / Han 8U plug

 

 

Power supply

 

Supply voltage

230 V AC (-10 ... +6%,

 

47 ... 63 Hz, approx. 6 VA) or

 

24 V AC/DC (24 V AC ± 10%,

 

47 ... 63 Hz, approx. 3 VA)

Permissible ripple (within the speci-

Approx. 2.5 Vpp

fied limits)

 

Dimensional drawings

SITRANS P pressure transmitter with supplementary electronics for 4- wire connection

Direct connection of the supplementary electronics to a SITRANS P pressure transmitter from the DS III HART series pro- duces a transmitter for four-wire connection.

The supplementary electronics cannot be attached to explosion- protected pressure transmitters. The supplementary electronics is fitted in a light metal housing which is mounted on the left side of the pressure transmitter.

Note on ordering:

The supplementary electronics has to be be ordered through the supplementary options of the pressure transmitter in question.

Technical specifications

SITRANS P, supplementary electronics for 4-wire connection Output

SITRANS P pressure transmitters with supplementary electronics for four- wire connection, dimension drawing, dimensions in mm (inch)

Schematics

Output signal

0 ... 20 mA or 4 ... 20 mA

Load

Max. 750 Ω

Voltage measurement

Linear (square-rooting in transmit-

 

ter if necessary)

Electrical isolation

Between power supply and input/

 

output

 

 

Measuring accuracy

To EN 60770-1

Conformity error (in addition to

0.15% of set span

transmitter)

 

Influence of ambient temperature

0.1% per 10 K

Power supply effect

0.1% per 10% change in volt-

 

age or frequency

Load effect

0.1% per 100% change

 

 

Rated conditions

 

Ambient temperature

-20 ... +80 °C (-4 ... +176 °F)

Storage temperature

-50 ... +85 °C (-58 ... +185 °F)

Degree of protection

IP54 to EN 60529

Electromagnetic compatibility

EN 50081, EN 50082

(EMC)

 

Terminals

1 HAN 8U/7D plug

2 plugs

AC 230 V

UC 24 V

Ia Output current

1 2 3 4 5 6

+-

I a

 

U H SL

6

7

SL

5

1

2

4

 

3

 

 

+ I a -

U H

 

 

6

7

 

6

7

SL

5

1

2

5

1

2

4

 

3

4

 

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

I a

 

 

 

 

 

 

 

 

 

 

+

-

 

 

 

 

 

U H

 

 

 

 

 

Han 7D

 

Han 7D

 

 

Han 7D

 

Han 8U

 

 

SL

Protective earth conductor UH Power supply

Supplementary electronics for 4-wire connection, connection diagram

2/134

Siemens FI 01 · 2009

Page 134
Image 134