© Siemens AG 2008

SITRANS P measuring instruments for pressure

Clamp-on seals of flange design

For gage pressure, differential pressure and flow

Selection and Ordering data

Order No. Ord. code

Clamp-on seal for flange-mounting for

SITRANS P pressure transmitters

for pressure

 

D) 7 M F 4 9 8 0 -

 

7MF4037 and 7MF4237 together with Order

 

 

code "V01" (vacuum-proof design) and

 

 

7MF80271); must be ordered separately, scope

 

 

of delivery: 1 off

 

 

 

for differential pressure and flow

D) 7 M F 4 9 8 3 -

 

7MF4433 or 7MF4434; order separately, scope

 

 

of delivery: 1 pair (set); Material: Completely of

 

 

stainless steel, mat. No. 1.4404/316L;

 

 

Process connection to EN 1092-1 or ASME

 

 

B16.5; sealing face to EN 1092-1, form B1,

 

 

or to ASME B16.5 RF 125 ... 250 AA

 

 

 

 

1 77 0 7 - 7B

777

Nominal diameter and nominal pressure

 

 

• DN 25

PN 6 ... 100

B

 

• DN 40

PN 6 ... 100

D

 

• DN 50

PN 6 ... 100

E

 

• DN 80

PN 6 ... 100

G

 

• DN 100

PN 6 ... 100

H

 

• 1 inch

Class 150 ... 2500

L

 

• 1½ inch

Class 150 ... 2500

M

 

• 2 inch

Class 150 ... 2500

N

 

• 3 inch

Class 150 ... 2500

P

 

• 4 inch

Class 150 ... 2500

Q

 

Other version

 

Z

J 1 Y

Add Order code and plain text:

 

 

Nominal diameter: ...; Nominal pressure: ...

 

 

Wetted parts materials

 

 

• Stainless steel 316L

 

 

 

- Without foil

 

A

 

- With PFA coating

 

D

 

- With ECTFE coating2)

F

 

• Monel 400, mat. No. 2.4360

G

 

• Hastelloy C276, mat. No. 2.4819

J

 

• Hastelloy C4, mat. No. 2.4610

U

 

• Tantalum

 

K

 

Other version

 

Z

K 1 Y

Add Order code and plain text:

 

 

Wetted parts materials: ...

 

 

Filling liquid

 

 

 

• Silicone oil M5

 

1

 

• Silicone oil M50

 

2

 

High-temperature oil

 

3

 

• Halocarbon oil (for measuring O2)

4

 

• Glycerin/water3)

 

6

 

• Food oil (FDA listed)

 

7

 

Other version

 

9

M 1 Y

Add Order code and plain text:

 

 

Filling liquid: ...

 

 

 

Connection to transmitter

 

 

• direct (only for 7MF4980)

0

 

through capillary, length:4)

 

 

• 1.0 m

(3.28 ft)

2

 

• 1.6 m

(5.25 ft)

3

 

• 2.5 m

(8.20 ft)

4

 

• 4.0 m

(13.1 ft)

5

 

• 6.0 m

(19.7 ft)

6

 

• 8.0 m

(26.25 ft)

7

 

• 10.0 m

(32.8 ft)

8

 

Other version

 

9

N 1 Y

Add Order code and plain text:

 

 

Length of capillary: ...

 

 

 

1)With 7MF8027 and the measuring cells Q, S, T and U also order the vacuum-tight version.

2)For vacuum on request.

3)Not suitable for use in low-pressure range.

4)Max. capillary length, see section "Technical description"

Selection and Ordering data

Order code

Further designs

 

 

 

Please add "-Z" to Order No. and specify Order code.

 

 

 

Spark arrestor

 

 

 

With spark arrestor for mounting on zone 0 (including

 

 

2

documentation)

 

 

 

 

 

• Pressure and absolute pressure

A01

 

 

• for differential pressure transmitters

A02

 

 

Quality inspection certificate (Factory calibration) to

C11

 

 

IEC 60770-2

 

 

 

 

 

 

Acceptance test certificate

C12

 

To EN 10204, section 3.1

 

 

 

 

 

 

 

 

 

Vacuum-proof design

V01

 

For use in low-pressure range

 

 

 

 

 

 

 

 

 

Calculation of span of associated pressure trans-

Y05

mitter

 

 

 

Enclose filled-in questionnaire with order

Note:

Suffix "Y01" required with pressure transmitter!

D) Subject to export regulations AL: N, ECCN: EAR99H.

Siemens FI 01 · 2009

2/177

Page 177
Image 177
Siemens P technical specifications 177, Delivery 1 off