Siemens technical specifications Sitrans P250 for differential pressure, Technische Daten

Models: P

1 234
Download 234 pages 4.66 Kb
Page 12
Image 12

© Siemens AG 2008

SITRANS P measuring instruments for pressure

Transmitters for gage, absolute and differential pressure

SITRANS P250 for differential pressure

Mode of operation

Overview

2

p1

p2

 

 

U

 

 

const.

 

 

U

I0, UB

 

I

SITRANS P250 transmitter for differential pressure

The SITRANS P250 transmitter measures the differential pres- sure of liquids and gases.

Benefits

High measuring accuracy

Sturdy stainless steel enclosure

For aggressive and non-aggressive media

For the measurement of the differential pressure of liquids and gases

Temperature-compensated measuring cell

Compact design

Application

The SITRANS P250 transmitter for differential pressure is prima- rily used in the following industries:

Chemical industry

Pharmaceutical industry

Food industry

Mechanical engineering

Shipbuilding

SITRANS P250 pressure transmitter, function diagram

The piezo-resistive ceramic measuring cell (membrane) has a Wheatstone bridge circuit, on which the operating pressure P1 and P2 of the media acts at both ends.

The voltage output from the measuring cell is converted by an amplifier into an output current of 4 to 20 mA or an output voltage of 0 to 5 or 10 V DC.

The output current and voltage are linearly proportional to the in- put pressure.

Technische Daten

SITRANS P250 differential pressure transmitter

Application

 

Differential pressure transmitter

Liquids and neutral gases

 

 

Mode of operation

 

Measuring principle

Piezo-resistive measuring cell

 

(ceramic diaphragm)

 

 

Input

 

Measured variable

Differential pressure

Measuring range

0 ... 0.1 to 0 ... 25 bar

 

(0 ... 1.45 to 0 ... 363 psi)

Operating pressure

25 bar (363 psi) at a differential

 

pressure range < 6 bar (87 psi)

 

50 bar (725 psi) at a differential

 

pressure range > 10 bar (145 psi)

Burst pressure

1.5 x operating pressure

 

 

Output

 

Output signal

 

• Water supply

• Current output signal

4 ... 20 mA

 

 

Design

Main components:

• Stainless steel enclosure with piezo-resistive ceramic measur-

ing cell and (temperature-compensated) electronics module.

• Voltage output signal

0 ... 5 V and 0 ... 10 V DC

Load

 

3-wire

> 10 kΩ

2-wire

(UH - 11 V) / 0.02 A

 

 

Measuring accuracy

 

• Process connection made of stainless steel in diverse designs

(see Selection and ordering data)

• Electrical connection through connectors acc. to EN 175301-

803-A and round connectors M12, as well as with permanently

fixed cable

Function

The pressure transmitter measures the differential pressure of

liquids and gases.

Dynamic behavior (at 25°C (77°F), including conformity error, hystere- sis and repeatability)

Long-term drift acc. to IEC 60770

Influence of ambient temperature

Start of scale

Full-scale value

1 % of typical full-scale value, see "Measuring range" table

0.5 % of full-scale value/year

0.6 %/10 K of full-scale value

(1.2 %/10 K for measuring cell 0 ... 0.1 bar (1.45 psi))

0.22 %/10 K of full-scale value

(0.37 %/10 K for measuring cell 0 ... 0.1 bar (1.45 psi))

Dynamic behavior

Suitable for static and dynamic

 

measurements

Response time T99

< 5 ms

Load variation

< 50 Hz

2/12

Siemens FI 01 · 2009

Page 12
Image 12
Siemens technical specifications Sitrans P250 for differential pressure, Technische Daten