© Siemens AG 2008

SITRANS P measuring instruments for pressure

Transmitters for gage, absolute and differential pressure, flow and level

DS III series for gage and absolute pressure, with front-flush diaphragm

Selection and Ordering data

Order code

 

 

Further designs

 

HART

PA

FF

Add "-Z" to Order No. and specify Order

 

 

 

 

 

 

 

 

code.

 

 

 

 

 

 

 

 

 

Sanitary process connection to NEUMO

 

 

 

 

Connect S flange connection

 

 

 

 

certified to EHEDG

 

 

 

 

• DN 50, PN 16

Q63

￿

￿

￿

• DN 65, PN 10

 

 

 

 

Q64

￿

￿

￿

• DN 80, PN 10

Q65

￿

￿

￿

• DN 100, PN 10

Q66

￿

￿

￿

• DN 2“, PN 16

Q72

￿

￿

￿

• DN 2½“, PN 10

Q73

￿

￿

￿

• DN 3“, PN 10

 

 

 

 

Q74

￿

￿

￿

• DN 4“, PN 10

Q75

￿

￿

￿

Aseptic threaded socket to DIN 11864-1

 

 

 

 

 

 

 

 

Form A

 

 

 

 

• DN 50, PN 25

N33

￿

￿

￿

• DN 65, PN 25

N34

￿

￿

￿

• DN 80, PN 25

N35

￿

￿

￿

• DN 100, PN 25

N36

￿

￿

￿

Aseptic flange with notch to DIN 11864-2

 

 

 

 

 

 

 

 

Form A

 

 

 

 

• DN 50, PN 16

N43

￿

￿

￿

• DN 65, PN 16

N44

￿

￿

￿

• DN 80, PN 16

N45

￿

￿

￿

• DN 100, PN 16

N46

￿

￿

￿

Aseptic flange with groove to DIN 11864-2

 

 

 

 

 

 

 

 

Form A

 

 

 

 

• DN 50, PN 16

N43 +

￿

￿

￿

 

P11

 

 

 

• DN 65, PN 16

N44 +

￿

￿

￿

 

P11

 

 

 

• DN 80, PN 16

N45 +

￿

￿

￿

 

P11

 

 

 

• DN 100, PN 16

 

 

 

 

N46 +

￿

￿

￿

 

P11

 

 

 

Aseptic clamp with groove to DIN 11864-3

 

 

 

 

 

 

 

 

Form A

 

 

 

 

• DN 50, PN 25

N53

￿

￿

￿

• DN 65, PN 25

N54

￿

￿

￿

• DN 80, PN 16

N55

￿

￿

￿

• DN 100, PN 16

N56

￿

￿

￿

 

 

 

 

 

1)Special Viton seal included in delivery.

2)Lower measuring limit -100 mbar g (1.45 psi g).

3)The weldable socket can be ordered under accessories

4)The maximum temperatures of the medium depend on the respective cell fillings.

Selection and Ordering data

Order code

 

 

Additional data

 

HART

PA

FF

Add "-Z" to Order No. and specify Order

 

 

 

 

code.

 

 

 

 

Measuring range to be set

Y01

￿

 

 

 

 

 

 

2

Specify in plain text (max. 5 digits):

 

 

 

 

Y01: ... up to ... mbar, bar, kPa, MPa, psi

 

 

 

 

Measuring point number (TAG No.)

Y15

￿

￿

￿

Max. 16 characters, specify in plain text:

 

 

 

 

Y15:

 

 

 

 

Measuring point text

Y16

￿

￿

￿

Max. 27 characters, specify in plain text:

 

 

 

 

Y16:

 

 

 

 

Setting of pressure indicator in pressure

Y21

￿

￿

￿

units

 

 

 

 

Specify in plain text (standard setting: mA):

Y21: mbar, bar, kPa, MPa, psi, ...

Note:

The following pressure units can be selected: bar, mbar, mm H2O*), inH2O*), ftH2O*), mmHG, inHG, psi, Pa, kPa, MPa, g/cm2, kg/cm2, Torr, ATM oder %

*) ref. temperature 20 °C

Preset bus address

Y25

￿

(possible between 1 and 126)

 

 

 

 

Specify in plain text:

 

 

Y25:

 

 

Only "Y01" and "Y21" can be factory preset

 

 

￿ = available

 

 

Ordering example

Item line:

7MF4133-1DB20-1AB7-Z

B line:

A22 + Y01 + Y21

C line:

Y01: 1 ... 10 bar (14.5 ... 145 psi)

C line:

Y21: bar (psi)

Siemens FI 01 · 2009

2/85

Page 85
Image 85
Siemens P technical specifications Additional data