© Siemens AG 2008

SITRANS P measuring instruments for pressure

Transmitters for food, pharmaceuticals and biotechnology

SITRANS P300 for gage and absolute pressure

 

 

 

 

Selection and Ordering data

Order code

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Further designs

 

HART

PA

FF

 

 

 

 

Add "-Z" to Order No. and specify Order

 

 

 

 

 

 

 

 

code.

 

 

 

 

2

 

 

 

Sanitary process connection to

 

 

 

 

 

 

 

NEUMO Connect S flange connection

 

 

 

 

 

 

 

certified to 3A and EHEDG

 

 

 

 

 

 

 

 

• DN 50, PN 16

Q63

￿

￿

￿

 

 

 

 

 

• DN 65, PN 10

Q64

￿

￿

￿

 

 

 

 

• DN 80, PN 10

 

 

 

 

 

Q65

￿

￿

￿

 

 

 

 

• DN 100, PN 10

Q66

￿

￿

￿

 

 

 

 

 

• DN 2“, PN 16

Q72

￿

￿

￿

 

 

 

 

• DN 2½“, PN 10

Q73

￿

￿

￿

 

 

 

 

• DN 3“, PN 10

Q74

￿

￿

￿

 

 

 

 

• DN 4“, PN 10

 

 

 

 

 

Q75

￿

￿

￿

 

 

 

 

Aseptic threaded socket to DIN 11864-1

 

 

 

 

 

 

 

 

Form A

 

 

 

 

 

 

 

 

• DN 50, PN 25

N33

￿

￿

￿

 

 

 

 

 

• DN 65, PN 25

N34

￿

￿

￿

 

 

 

 

• DN 80, PN 25

N35

￿

￿

￿

 

 

 

 

• DN 100, PN 25

N36

￿

￿

￿

 

 

 

 

Aseptic flange with notch to DIN 11864-2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Form A

 

 

 

 

 

 

 

 

• DN 50, PN 16

N43

￿

￿

￿

 

 

 

 

 

• DN 65, PN 16

N44

￿

￿

￿

 

 

 

 

• DN 80, PN 16

N45

￿

￿

￿

 

 

 

 

• DN 100, PN 16

 

 

 

 

 

N46

￿

￿

￿

 

 

 

 

Aseptic flange with groove to DIN 11864-2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Form A

 

 

 

 

 

 

 

 

• DN 50, PN 16

N43 +

￿

￿

￿

 

 

 

 

 

 

P11

 

 

 

 

 

 

 

• DN 65, PN 16

 

 

 

 

 

N44 +

￿

￿

￿

 

 

 

 

 

P11

 

 

 

 

 

 

 

• DN 80, PN 16

N45 +

￿

￿

￿

 

 

 

 

 

P11

 

 

 

 

 

 

 

• DN 100, PN 16

 

 

 

 

 

N46 +

￿

￿

￿

 

 

 

 

 

P11

 

 

 

 

 

 

 

Aseptic clamp with groove to DIN 11864-3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Form A

 

 

 

 

 

 

 

 

• DN 50, PN 25

N53

￿

￿

￿

 

 

 

 

 

• DN 65, PN 25

N54

￿

￿

￿

 

 

 

 

• DN 80, PN 16

N55

￿

￿

￿

 

 

 

 

• DN 100, PN 16

N56

￿

￿

￿

 

 

 

 

 

 

 

 

 

1)When the manufacture’s certificate M (calibration certificate) has to be ordered for transmitters with diaphragm seals, it is recommended only to order this certificate exclusively with the diaphragm seals. The measuring accuracy of the total combination is certified here.

2)Whe the acceptance test certificate 3.1 for transmitters with direct-con- nected diaphragm seals is ordered, this certificate must also be ordered with the corresponding seals.

3)Special Viton seal included in delivery.

4)Lower measuring limit -100 mbar g (1.45 psi g).

5)The weldable socket can be ordered under accessories

6)Certified to 3A.

The maximum temperatures of the medium depend on the respective cell fillings.

7)3A certification only if used in conjunction with 3A-compliant sealing rings.

 

 

Selection and Ordering data

 

 

Order code

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Additional data

 

 

 

 

 

HART

PA

FF

 

 

Add "-Z" to Order No. and specify Order

 

 

 

 

 

 

code.

 

 

 

 

 

 

 

 

 

 

Measuring range to be set

 

 

Y01

￿

 

 

 

 

Specify in plain text V (max. 5 digits):

 

 

 

 

 

 

 

 

 

 

 

Y01: ... up to ... mbar, bar, kPa, MPa, psi

 

 

 

 

 

 

Measuring point number (TAG No.)

Y15

 

 

 

 

 

￿

￿

￿

 

 

Max. 16 characters, specify in plain text:

 

 

 

 

 

 

 

 

 

 

 

Y15:

 

 

 

 

 

 

 

 

 

Measuring point text

 

 

 

 

Y16

 

 

 

 

 

 

 

 

 

￿

￿

￿

 

 

Max. 27 characters, specify in plain text:

 

 

 

 

 

 

 

 

 

 

 

Y16:

 

 

 

 

 

 

 

 

 

Entry of HART TAG

 

 

 

 

Y17

￿

 

 

 

 

 

 

 

 

 

 

 

 

Max. 8 characters, specify in plain text:

 

 

 

 

 

 

 

 

 

 

 

Y17:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Setting of pressure indication in pressure

Y21

￿

￿

￿

 

 

units

 

 

 

 

 

 

 

 

 

 

Specify in plain text (standard setting: mA):

 

 

 

 

 

 

 

 

 

 

 

Y21: mbar, bar, kPa, MPa, psi, ...

 

 

 

 

 

 

 

 

Note:

 

 

 

 

 

 

 

 

 

 

The following pressure units can be selected:

 

 

 

 

 

 

bar, mbar, mm H O*), inH

2

O*), ftH

2

O*),

 

 

 

 

 

2

 

 

 

 

 

 

 

 

mmHG, inHG, psi, Pa, kPa, MPa, g/cm2,

 

 

 

 

 

 

kg/cm2, Torr, ATM or %

 

 

 

 

 

 

 

 

 

*) ref. temperature 20 °C

 

 

 

 

 

 

 

 

 

 

Setting of pressure indicator in

 

 

Y22 +

￿

 

 

 

 

non-pressure units

 

 

 

 

Y01

 

 

 

 

 

Specify in plain text:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Y22: ..... up to ..... l, m3, m, USg, ...

 

 

 

 

 

(specification of measuring range in pressure

 

 

 

 

 

units "Y01" is essential, unit with max. 5 char-

 

 

 

 

 

acters)

 

 

 

 

 

 

 

 

 

 

Preset bus address

 

 

 

 

Y25

 

 

 

 

 

 

 

 

 

 

￿

￿

 

 

possible between 1 ... 126)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Specify in plain text:

 

 

 

 

 

 

 

 

 

 

Y25:

 

 

 

 

 

 

 

 

 

 

Only "Y01" and "Y21" can be factory preset

 

 

 

 

 

 

￿ = available

 

 

 

 

 

 

 

 

Ordering example

Item line:

7MF8023-1DB24-1AB7-Z

B line:

A02 + Y01 + Y21

C line:

Y01: 1 ... 10 bar (14.5 ... 145 psi)

C line:

Y21: bar (psi)

2/42

Siemens FI 01 · 2009

Page 42
Image 42
Siemens P Q63, Q64, Q65, Q66, Q72, Q73, Q74, Q75 Aseptic threaded socket to DIN Form a, N33, N34, N35, N43, N44, N45, N46