Siemens P 132, Nom. diam Nom. press, 200 138 160 150 or 220 115 158 180 235 162 190

Models: P

1 234
Download 234 pages 4.66 Kb
Page 132
Image 132
2) 3)

© Siemens AG 2008

SITRANS P measuring instruments for pressure

Transmitters for gage, absolute and differential pressure, flow and level

DS III series for level

Dimensional drawings

approx. 30 (1.18)5)

 

 

185

2

100 (3.94)

6

 

 

 

3

 

 

2

 

 

 

 

 

 

 

 

L

 

 

 

 

9

 

 

 

 

 

8

 

 

 

d

d4 k D

 

 

 

5

 

3

1

54 (2.1)

108 (4.25)

 

 

 

 

n x d 2

 

 

approx. 96 (3.78)

b

 

 

f

 

 

 

 

 

 

144 (5.67)

15

 

51

(0.6)

 

 

 

(2.0)

74 (2.9)

 

 

 

51)

.5)

 

 

90 (3.6)4)

165 (6

 

 

 

Space for rotation of housing

1Process connection of low pressure side ¼-18 NPT (EN 61 518)

2 Blanking plug

3 Electrical connection:

screwed gland Pg 13.5 (adapter) 2) 3),

screwed gland M20x1.5, screwed gland ½-14 NPT or

Han 7D/ Han 8U plug41)

4 Terminal side

5Electronics side, digital display (longer overall length for cover with window)

6 Protective cover over keys

8 Sealing screw with valve (option)

9 Screw cover safety bracket (only for type of protection "Explosion-proof enclosure", not shown in the drawing)

1) Allow approx. 20 mm (0.79 inch) thread length in addition

2) Not with type of protection "Explosion-proof enclosure"

3) Not with type of protection "FM + CSA [is + xp]"

4)92 mm (3.62 inch) for minimum distance to permit rotation without indicator

5)Approx. 45 mm (1.77 inch) for Pg 13.5 with adapter

651)

SITRANS P pressure transmitters, DS III HART series for level, including mounting flange, dimensions in mm (inch)

Connection to EN 1092-1

Nom. diam.

Nom. press.

b

D

d

d2

d4

d5

dM

f

k

n

L

 

 

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

 

 

 

 

 

 

 

 

 

 

 

 

 

DN 80

PN 40

24

200

90

18

138

76

72 1)

2

160

8

0, 50, 100,

 

 

 

 

 

 

 

 

 

 

 

 

150 or 200

DN 100

PN 40

20

220

115

18

158

94

89

2

180

8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PN 40

24

235

115

22

162

94

89

2

190

8

 

Connection to ASME B16.5

Nom. diam.

Nom. press.

b

D

d2

d4

d5

dM

f

k

n

L

 

lb/sq.in.

inch

inch

inch

inch

inch

inch

inch

inch

 

inch

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(mm)

(mm)

(mm)

(mm)

(mm)

(mm)

(mm)

(mm)

 

(mm)

 

 

 

 

 

 

 

 

 

 

 

 

3 inch

150

0.94

7.5

0.75

5

3

2.81 1)

0.06

6

4

0, 2, 3.94, 5.94 or 7.87

 

 

(23.8)

(190.5)

(19.0)

(127)

(76)

(72)

(1.6)

(152.4)

 

(0, 50, 100, 150 or 200)

 

 

 

 

 

 

 

 

 

 

 

 

 

300

1.12

8.25

0.87

5

3

2.81 1)

0.06

6.69

8

 

 

 

(28.6)

(209.5)

(22.2)

(127)

(76)

(72)

(1.6)

(168.3)

 

 

4 inch

150

0.94

9

0.75

6.19

3.69

3.5

0.06

7.5

8

 

 

 

(23.8)

(228.5)

(19.0)

(157.2)

(94)

(89)

(1.6)

(190.5)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

300

1.25

10

0.87

6.19

3.69

3.5

0.06

7.88

8

 

 

 

(31.7)

(254)

(22.2)

(157.2)

(94)

(89)

(1.6)

(200)

 

 

 

 

 

 

 

 

d: Internal diameter of gasket to DIN 2690

 

 

1)

89 mm = 3½ inch with tube length L = 0.

 

dM: Effective diaphragm diameter

 

 

 

 

 

 

 

 

 

2/132

Siemens FI 01 · 2009

Page 132
Image 132
Siemens P technical specifications 132, Nom. diam Nom. press, 200 138 160 150 or 220 115 158 180 235 162 190