© Siemens AG 2008

SITRANS P measuring instruments for pressure

Transmitters for gage, absolute and differential pressure

ZD series for gage and absolute pressure

Selection and Ordering data

Order No. Ord. Code

 

SITRANS P pressure transmitters, ZD

 

7M F 1 5 8 0 -

 

 

series for gage and absolute pressure

 

 

 

 

Conformity error 0.25%, range adjustment

 

7777 0

777

2

1 : 5 (max. 1 : 10), housing and process

 

 

 

connection made of stainless steel,

 

 

 

membrane made of ceramic, 2-wire system,

 

 

 

 

output 4 ... 20 mA

 

 

 

 

 

Input variable

 

 

 

 

 

Gage pressure

 

}

1

 

 

Absolute pressure

 

}

2

 

 

 

 

F)

 

 

 

Measured range

Span

 

 

 

 

0 ... 2 bar

0 ... 0.4 / 2 bar

}

D

 

 

(0 ... 29 psi)

(0 ... 5.8 / 29 psi)

 

 

 

 

0 ... 10 bar

0 ... 2 / 10 bar

}

E

 

 

(0 ... 145 psi)

(0 ... 5.8 / 145 psi)

 

 

 

 

0 ... 50 bar

0 ... 10 / 50 bar

}

F

 

 

(0 ... 725 psi)

(0 ... 145 / 725 psi)

 

 

 

 

0 ... 200 bar

0 ... 40 / 200 bar

}

G

 

 

(0 ... 2900 psi)

(0 ... 580 / 2900 psi)

 

 

 

 

0 ... 400 bar

0 ... 80 / 400 bar

}

H

 

 

(0 ... 5800 psi)

(0 ... 1160 / 5800 psi)

 

 

 

 

Other version (on request)

 

Z

J 1 Y

 

add Order Code and plain text:

 

 

 

 

Process connection:

 

 

 

 

Process connection

 

 

 

 

 

G½B male thread and G1/ B female thread

}

A

 

 

G½B to EN 837-1

8

F)

B

 

 

 

 

 

Female thread ½-14 NPT

F)

C

 

 

G 1“ male thread

 

F)

M

 

Design

 

 

 

Process connection vertically downwards,

}

 

1

thread in connector M16x1.5

 

 

 

Process connection horizontally to rear,

 

 

2

thread in connector M16x1.5

 

 

 

Process connection vertically downwards,

}

 

3

thread in connector ½"-14 NPT

 

 

 

Process connection horizontally to rear,

 

 

4

 

 

thread in connector ½"-14 NPT

 

 

 

 

 

 

 

Selection and Ordering data

Order Code

Further designs

 

 

 

Please add "Z" to Order No. and specify Order

 

 

 

 

 

 

code(s) and plain text.

 

 

 

 

 

 

 

Quality inspection certificate (Factory cali-

C1

1

 

bration) to IEC 60770-2 supplied

 

 

 

 

 

 

 

Factory certificate

C1

4

 

to EN 10204-2.2 supplied

 

 

 

Oxygen application, oil and grease-free

E1

0

 

cleaned

 

 

 

(only in conjunction with the sealing material

 

 

 

Viton between sensor and enclosure and only

 

 

 

in conjunction with measuring ranges >= 1

 

 

 

bar g and 1 bar abs)

 

 

 

Sealing material FEP between sensor and

E2 0

housing, instead of Viton

 

 

 

max. operating pressure 15 bar (218 psi),

 

 

 

max. measuring temperature -10 ... +50 °C

 

 

 

 

 

 

 

Additional data

 

 

 

Please add "Z" to Order No. and specify Order

 

 

 

code(s) and plain text.

 

 

 

Measuring range to be set,

Y0

1

 

specify in plain text:

 

 

 

Y01: ... up to ... mbar, bar, kPa, MPa, psi

 

 

 

 

 

 

 

TAG number made of stainless steel

Y1

5

 

Accessories

Order No.

Quality inspection certificate (Factory

7MF1564-8CC11

 

calibration) to IEC 60770-2 supplied later,

 

 

 

specify factory of transmitter.

 

 

 

 

 

 

 

} Available ex stock

F) Subject to export regulations AL: 9I999, ECCN: N.

2/20

Siemens FI 01 · 2009

Page 20
Image 20
Siemens P technical specifications Series for gage and absolute pressure, Input variable, Measured range Span, Order No