Siemens P 153, Technical specifications Temperature error Diaphragm seals, 058 073 500

Models: P

1 234
Download 234 pages 4.66 Kb
Page 153
Image 153

© Siemens AG 2008

SITRANS P measuring instruments for pressure

Remote seals for transmitters and pressure gages

Technical description

Technical specifications Temperature error Diaphragm seals

Temperature errors of diaphragm seals when connected to pressure transmitters for pressure, absolute pressure, differential pres- sure (single-sided) and level

 

Nominal diameter/

Diaphragm

Temperature

Temperature error of

Temperature

Recommended

2

 

design

diameter

error of remote

capillary

 

error of process

min. spans (guid-

 

 

 

 

 

seal

 

 

 

flange/connec-

ance values,

 

 

 

 

 

 

 

 

 

tion spigot

observe temp.

 

 

 

 

 

 

 

 

 

 

 

error)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

mm

(inch)

mbar/

(psi/

mbar/

(psi/

mbar/

(psi/

mbar

(psi)

 

 

 

 

 

10 K

10 K)

(10 K mKap)

(10 K mKap))

10 K

10 K)

 

 

 

Sandwich

DN 50 without tube

59

(2.32)

1.5

(0.022)

2

(0.029)

2

(0.029)

200

(2.90)

 

design or with

 

 

 

 

 

 

 

 

 

 

 

 

DN 50 with tube

48

(1.89)

5

(0.073)

10

(0.145)

10

(0.145)

500

(7.25)

 

flange to

 

EN 1092-1

 

 

 

 

 

 

 

 

 

 

 

 

DN 80 without tube

89

(3.50)

0.2

(0.003)

0.2

(0.003)

0.2

(0.003)

100

(1.45)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DN 80 with tube

72

(2.83)

1

(0.015)

1

(1.015)

1

(1.015)

250

(3.63)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DN 100 without tube

89

(3.50)

0.4

(0.006)

0.4

(0.006)

0.4

(0.006)

100

(1.45)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DN 100 with tube

89

(3.50)

0.4

(0.006)

0.4

(0.006)

0.4

(0.006)

100

(1.45)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DN 125 without tube

124

(4.88)

0.2

(0.003)

0.1

(0.002)

0.1

(0.002)

20

(0.29)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DN 125 with tube

124

(4.88)

0.2

(0.003)

0.1

(0.002)

0.1

(0.002)

20

(0.29)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sandwich

2 inch without tube

59

(2.32)

1.5

(0.022)

2

(0.029)

2

(0.029)

200

(2.90)

 

design or with

 

 

 

 

 

 

 

 

 

 

 

 

2 inch with tube

48

(1.89)

5

(0.073)

10

(0.145)

10

(0.145)

500

(7.25)

 

flange to

 

 

 

 

 

 

 

 

 

 

 

 

 

3 inch without tube

89

(3.50)

0.2

(0.003)

0.2

(0.003)

0.2

(0.003)

100

(1.45)

 

ASME B16.5

 

 

3 inch with tube

72

(2.83)

1

(0.015)

1

(1.015)

1

(1.015)

250

(3.63)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4 inch without tube

89

(3.50)

0.4

(0.006)

0.4

(0.006)

0.4

(0.006)

100

(1.45)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4 inch with tube

89

(3.50)

0.4

(0.006)

0.4

(0.006)

0.4

(0.006)

100

(1.45)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5 inch without tube

124

(4.88)

0.2

(0.003)

0.1

(0.002)

0.1

(0.002)

20

(0.29)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5 inch with tube

124

(4.88)

0.2

(0.003)

0.1

(0.002)

0.1

(0.002)

20

(0.29)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Remote seal

DN 25

25

(0.98)

20

(0.290)

60

(0.870)

60

(0.870)

6000

(87)

 

with union nut to

 

 

 

 

 

 

 

 

 

 

 

 

DN 32

32

(1.26)

8

(0.116)

25

(0.363)

25

(0.363)

4000

(58)

 

DIN 11851

 

 

 

 

 

 

 

 

 

 

 

 

DN 40

40

(1.57)

4

(0.058)

10

(0.145)

10

(0.145)

2000

(29)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DN 50

52

(2.05)

4

(0.058)

5

(0.073)

5

(0.073)

500

(7.25)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DN 65

59

(2.32)

3

(0.044)

4

(0.058)

4

(0.058)

500

(7.25)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DN 80

72

(2.83)

1

(0.015)

1

(0.015)

1

(0.015)

250

(3.63)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Remote seal

DN 25

25

(0.98)

20

(0.290)

60

(0.870)

60

(0.870)

6000

(87)

 

with threaded

 

 

 

 

 

 

 

 

 

 

 

 

DN 32

32

(1.26)

8

(0.116)

25

(0.363)

25

(0.363)

4000

(58)

 

socket to

 

 

 

 

 

 

 

 

 

 

 

 

 

DIN 11851

DN 40

40

(1.57)

4

(0.058)

10

(0.145)

10

(0.145)

2000

(29)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DN 50

52

(2.05)

4

(0.058)

5

(0.073)

5

(0.073)

500

(7.25)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DN 65

59

(2.32)

3

(0.044)

4

(0.058)

4

(0.058)

500

(7.25)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DN 80

72

(2.83)

1

(0.015)

1

(0.015)

1

(0.015)

250

(3.63)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Clamp connec-

1½ inch

32

(1.26)

8

(0.116)

25

(0.363)

25

(0.363)

4000

(58)

 

tion

 

 

 

 

 

 

 

 

 

 

 

 

2 inch

40

(1.57)

4

(0.058)

10

(0.145)

10

(0.145)

2000

(29)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2½ inch

59

(2.32)

3

(0.044)

5

(0.073)

5

(0.073)

500

(7.25)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3 inch

72

(2.83)

1

(0.015)

1

(0.015)

1

(0.015)

250

(3.63)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Miniature dia-

G1B

25

(0.98)

20

(0.290)

60

(0.870)

60

(0.870)

6000

(87)

 

phragm seal

 

 

 

 

 

 

 

 

 

 

 

 

G1½B

40

(1.57)

4

(0.058)

10

(0.145)

10

(0.145)

2000

(29)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G2B

52

(2.05)

4

(0.058)

5

(0.073)

5

(0.073)

500

(7.25)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Remarks:

Values apply for the filling liquids silicone oil M5, silicone oil M50, high-temperature oil, halocarbon oil and food oil (FDA listed).

Half the values apply to glycerin/water mixture as the filling liquid.

Values apply to stainless steel as the diaphragm material.

Siemens FI 01 · 2009

2/153

Page 153
Image 153
Siemens 153, Technical specifications Temperature error Diaphragm seals, Inch Mbar Psi 10 K 10 K ⋅ m Kap, 058 073 500