Questionnaire

for hydrostatic level measurements

2

Order date: _______________________________________________

Processing date: __________________________________________

Ordering code (customer): _________________________________

Ordering code (supplier): __________________________________

Customer reference:_______________________________________

Measuring point: __________________________________________

Position:__________________________________________________

Dimensions: ______________________________________________

Pressure:

bar

Temperature:

K

Measuring range:

cm

(please mark with cross)

 

Order No. of transmitter 1):

 

7

 

M

 

F

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Y01

°C

m

–Z

The different pressures and tem- peratures (densities) in the vessel and in the reference column result in an offset in the start-of-scale and full-scale values.

The calibration data are deter- mined in addition.

It is also checked whether – as a result of the range offset – the ordered transmitter is suitable for this measurement.

Please supply the following characteristic data so that we can calculate the measuring range, start-of-scale value, full-scale value and calibration data:

Please mark type of boiler with a cross: Closed1)

Open or not under pressure2)

Medium ____________________

Licensed boiler pressure (absolute)

 

 

_______________

bar

Operating pressure (absolute)

Lowest

 

_______________

bar

 

Normal3)

 

_______________

bar

 

Highest

 

_______________

bar

Temperature of reference column (cold)

 

 

_______________

K

Distance between measuring points (dimension according to sketch) HV = _________

m

Measuring range4) = start-of-scale value to full-scale value

 

 

 

 

Start-of-scale value

HU =___________

m

 

Full-scale value

 

HO =___________

m

Position of equalizing vessel above bottom measuring

 

_______________

m

point if different from HV

 

 

 

 

 

 

Please mark pressure correction of level with a cross:

No

 

 

 

 

Yes4)

 

 

1)Reference line filled with condensation! Falling differential pressure with increasing level.

2)Reference line without gas or filled with gas (air). Rising differential pressure with increasing level.

3)If not specified otherwise, this value is assumed as the calculation pressure of the level meter. The input signal (differential pressure) depends on the density (pressure and temperature).

The influence is practically negligible for a lowest liquid level of 20 to 30% of the distance between the measuring points.

4)If a pressure correction of the level is required, the measuring range must be the same as the distance between the measuring points, and the transmitter is designed for the calculation pressure of 1 bar (absolute).

Pressure correction means: the static pressure and the temperature are measured separately and calculated by a correction computer or measured-value computer.